Installing Vent Components; Venting Out The Rear Vent; Venting Out The Top Vent; Attaching The First Vent Component To The Starting Collars - Heat-N-Glo SL-950TR Installer's Manual

Hide thumbs Also See for SL-950TR:
Table of Contents

Advertisement

!
!
!
!
Insert screwdriver
or similar object
here to remove cap.
HEAT
SHIELD
DISCARD
INSULATION
CUT HERE
SEAL
INSULATION,
SEAL
CAP
DISCARD
CAP
BOTH
PIECES
HEAT
SHIELD
STARTING
COLLAR
FIRST VENT
COMPONENT
!
39
3/8”
(9.5mm)
STOVE
SEALANT
BEAD
1 INCH
(25.4mm)