R.V.R. Electronica TEX30LCD User Manual page 27

Table of Contents

Advertisement

ELETTRONICA
A brief description of the procedure is provided below:
• Connect the PC serial port COM to the SERVICE connector on the rear panel
of TEX30/50/100/150/300LCD using a standard Male DB9 - Female DB9 serial
cable.
• Power on the exciter;
• Launch the serial communication software;
• Set communication parameters as follows:
Baud Rate: 19200
Data Bit: 8
Parity: None
Stop Bit: 1
Flow control: None;
• Activate Caps-Lock through the communication software and send string CODE
followed by the 6-character station ID code followed by Enter.
NOTE: To be treated as valid, the code must be made up of 6 alphanumeric
characters and must contain no blank spaces; if acknowledged as valid, code is
echoed back to the terminal, illegal codes are not echoed.
5.5.2 Power UP/DOWN Option
The Power UP/DOWN option modifies the signal receive function for the signals
present at the telemetry connector.
RF section on / off control signals are treated as control signals for RF output
power level to allow for UP/DOWN setting.
The UP or DOWN command is provided by switching the corresponding signal at
the connector to ground for at least 500mS (pin features internal pull-up to power
supply).
Configuration of DB15F telemetry connector (Remote):
Pin Standard Function
14 On cmd
15 Off cmd
User Manual
Enables the RF power supply
Disables the RF power supply
Rev. 1.0 - 29/11/12
TEX30/50/100/150/300LCD
UP/DOWN Power Function
Up cmd
Increases the RF power supply
Down cmd
Reduces the RF power supply
23