R.V.R. Electronica TEX30LCD User Manual page 23

Table of Contents

Advertisement

ELETTRONICA
Mod
PgD
PgR
NOTE: This alarm does not trip any contacts in the DB15 "Remote" connector and
is only available in systems equipped with telemetry.
5.4.2 Power menu(Pwr)
This screen holds all readings related to equipment output power:
Fwd
Rfl
Note that these are readings, rather than settings, and cannot be edited (note
the empty triangle). To change power setting, go to the default menu as outlined
earlier.
User Manual
Modifies modulation display (toggles between "x1" and "x10"). In "x10"
mode, instantaneous deviation indication is multiplied by a factor of 10,
and the bar meter on the default menu will reflect 7.5 kHz instead of
75 kHz. This display mode is convenient when you wish to display low
deviation levels, such as those caused by pilot tone or subcarriers.
Modifies Power Good threshold for forward power. The Power Good
rate is a percent of equipment rated power (30/50/100/150/300 W for
TEX30/50/100/150/300LCD respectevely), not of forward output power.
This means that this threshold set at 50% will give 15/25/50/75/150 W,
respectively, regardless of set power level. The Power Good feature
enables output power control and reporting. When output power drops
below set Power Good threshold, the equipment changes the state of
pin [7] of the DB15 "Remote" connector located on the rear panel.
Modifies Power Good threshold for reflected power. The Power Good
rate is a percent of equipment rated power (3/5/10/15/30 W for TEX30/
50/100/150/300LCD respectevely), not of reflected output power. This
means that this threshold set at 5% will give 0,15/0,25/0,50/0,75/1,5
W, respectively, regardless of set power level. The Power Good feature
enables output power control and alarm management.
Forward power reading.
Reflected power reading.
Rev. 1.0 - 29/11/12
TEX30/50/100/150/300LCD
Menu 5
1
/ 32

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tex50lcdTex150lcdTex100lcdTex300lcd

Table of Contents