As soon as operating conditions are restored, power output is re-enabled with the
same settings in use prior to the alarm condition.
Under 20kHz, no modulation occurs. After a preset time of about 5 minutes (not
editable), a NO AUDIO condition is indicated in the main screen, but power is not
inhibited.
State 2
To gain access to a submenu, select menu name (name is highlighted by cursor)
using button or and press the ENTER button.
To return to the default menu (menu 1), simply press ESC again.
5.4.1 Operation Menu (Fnc)
In this menu, you can toggle exciter power output On/Off, set deviation display
mode and the threshold rate for Forward (PgD) or Reflected (PgR) Power
Good.
To edit an item, highlight the appropriate line using the
and
buttons
and then press and hold the ENTER button until the command is accepted.
This way, Pwr setting is toggled between On and Off and Mod setting is toggled
between "x1" and "x10". To edit the Power Good rate, simply select item "PgD" or
"PgR" and edit its value using the UP and DOWN buttons; finally, press ENTER
to confirm.
Menu 4
Pwr
Enables (ON) or disables (OFF) exciter power output.