CAUTION: THE FIREPLACE IN WHICH
THIS GAS INSERT IS TO BE INSTALLED
MUST BE THOROUGHLY CLEANED IF IT
HAS BEEN USED TO BURN WOOD OR
SYNTHETIC LOGS. HAVE THE CHIMNEY
AND ALL INSIDE SURFACES OF THE
FIREPLACE BRUSHED AND VACUUMED
SO THAT NO SOOT, EMBERS, OR LOOSE
COMBUSTION DEPOSITS CAN BE DRAWN
INTO THE HEAT CIRCULATION BLOWER
AND BLOWN INTO THE LIVING AREA. IF
ANY PORTION OF THE CHIMNEY SYSTEM
SHOWS SIGNS OF STRUCTURAL OR
MECHANICAL WEAKNESSES, SUCH AS:
CRACKS, LEAKY JOINTS, CORRODED OR
WARPED SURFACES, THE FAULTY POR-
TION MUST BE REPAIRED OR REPLACED
PRIOR TO INSTALLING THIS APPLIANCE.
Step 3: UNPACK THE INSERT - Remove
the top and side cartons. Remove all the
inner packages and packing materials and
discard.
f i r e - p a r t s . c o m
Step 4: LIFT INSERT INTO POSITION (see
Fireplace Requirements on page 4 fi rst)
insert into position in front of the fi replace where
unit is to be installed. Discard bottom carton
Step 5: REMOVE STANDARD GLASS DOOR
ASSEMBLY.
WARNING: NEVER OPERATE UNIT WITH-
OUT THE FRONT GLASS DOOR PANEL IN
PLACE AND SECURE.
WARNING: HANDLE GLASS DOOR WITH
EXTREME CARE! THE GLASS DOOR
ASSEMBLY IS SUSCEPTIBLE TO DAMAGE.
DO NOT SCRATCH WHILE HANDLING OR
WHILE REINSTALLING.
Remove the front door assembly from insert
as follows:
1) Open the 2 latches below the glass door
as shown in Figures 9 & 10.
Glass Door
Release latch on
each side (below door)
Figure 9
2) Swing the bottom of the door outward
(see Figure 10) and lift it off of fi rebox top.
Set door aside in a safe place.
Lift
Latches
Bottom Vee-fl ange
Door Frame
Figure 10
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
STEP 6: REMOVE PACKAGED MATERIALS
FROM INSIDE FIREBOX AND SET ASIDE (
set, bag of embers, bag of vermiculite,
propane conversion kit. and draft hood
sliding tool).
Step 7: INSTALL LP CONVERSION KIT (IF
NECESSARY) - Install the LP conversion kit
per instructions provided with kit.
Step 8: VENTING SYSTEM INSTALLATION
(Refer to Installation Instructions provided
with venting components).
VENTING REQUIREMENTS: This appliance
requires the use of 4" B-Vent or, a 4" UL
1777 listed gas vent liner from fl ue outlet
to the chimney termination to ensure proper
operation. Follow all vent manufacturer's
requirements and local building codes. The
vent termination must be in accordance with
the vent manufacturer's instructions.
Flex Liner Installation (see Figure 17 for
Top
Masonry Fireplace Installations and Figure
Flange
Door
18 for Factory Built Fireplaces):
Frame
• Flexible vent pipe is packaged and shipped
in its contracted state. When installing fl exible
Glass Door
vent pipe, its length may be expanded to twice
it contracted size. This appliance is approved
for 40 feet maximum vertical venting (from
the outlet to termination). A minimum fl ue
height of 12 feet is required.
• The fl exible vent pipe must NOT be allowed
to sag behind the insert or in the fi replace
fl ue.
log