INSTALLATION AND OPERATION MANUAL
EPA Certified
Wood-Burning
Fireplace Inserts
Retain These Instructions
For Future Reference
P/N 775,210M, Rev. B 12/2007
A French manual is available upon request. Order P/N 775,210CF.
Report #050-S-02b-2
Ce manuel d'installation est disponible en francais, simplement en faire la demande. Numéro de la
pièce 775,210CF.
These appliances must be properly installed and operated in order to prevent the
possibility of a house fire. Please read this entire installation and operation
manual before installing and using your wood stove. Failure to follow
these instructions could result in property damage, bodily injury or
US
Hot! Do not touch! The glass and surfaces of this appliance will
be hot during operation and will retain heat for a while after
shutting off the appliance. Severe burns may result.
Carefully supervise children in the same room as appliance.
Wood Fireplace Inserts
Legacy™/Elite™ Models C/E260
even death. Contact your local building or fire officials to obtain
a permit and information on any installation requirements
and inspection requirements in your area.
WARNINGS
Elite™ E260
Legacy™ C260

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products LEGACY/ELITE C260

  • Page 1 INSTALLATION AND OPERATION MANUAL EPA Certified Wood-Burning Fireplace Inserts Retain These Instructions For Future Reference P/N 775,210M, Rev. B 12/2007 A French manual is available upon request. Order P/N 775,210CF. Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la pièce 775,210CF.
  • Page 2: T Esting I Nformation

    esTing nformaTion This manual describes the installation and operation of the Legacy™/Elite™ C/E260 non-catalytic wood heaters. These heaters meet the U.S. Environmental Protection Agency’s emissions limits for wood heaters sold on or after July 1, 1990. This heater has been developed, tested, and constructed in accordance with the requirements of UL 1482, ULC S628 and HUD standards and is listed by OMNI Test Laboratories, Beaverton, OR.
  • Page 3: Table Of Contents

    ...2 esTing nformaTion ...2 eneral afeTy recauTions ...4 rafTing egaTive ressure arning ...4 reosoTe ...5 isPosal ...5 ...5 reak erioD ...5 ainT uring ...6 rick nsTallaTion ...7 equireD learances ...7 earTh roTecTion ...8 himney equiremenTs nsTallaTion roceDures asonry irePlace nsTallaTion reParaTion nserT nsTallaTion...
  • Page 4: D Rafting

    rafTing Your wood stove is dependent upon a properly functioning chimney for optimum performance. It is a high efficiency appliance that loses much less heat up the chimney than older appliances and fireplaces. For this reason it is important to match the stove to the chimney. The chimney has two functions: 1) It draws combustion air into the appliance (without air, no fuel will burn) and 2) It exhausts combustion by-products.
  • Page 5: A Sh D Isposal

    isPosal Ashes should be scooped out of a cool stove with a small metal shovel. Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal.
  • Page 6: B Rick I Nstallation

    rick nsTallaTion Legacy™/Elite™ C/E20 Brick Installation CAUTION: Wear gloves during brick installation in case of sharp edges inside the stove. Note: Installation of the baffle bricks and insulating blanket is easier when you can still access the flue outlet, (before connecting the flue pipe).
  • Page 7: Equired Learances

    equireD learances WARNING: BE ABSOLUTELY SURE THE DISTANCE BE- TWEEN THE HEATER AND THE SURFACE OF ANY COM- BUSTIBLE CONSTRUCTION IS NOT LESS THAN SHOWN ON THIS PAGE. Model C20 0” 20” 762mm 508mm E20 2” 17” 584mm 432mm C20 with mantel 17”...
  • Page 8: Nstallation Rocedures Asonry Himney

    himney equiremenTs The L ™/e ™ c/e260 inserts are approved for use in egacy Lite masonry fireplaces built to UBC Chapter 37 or equivalent with a minimum 30” opening at the front of the fireplace. Do not remove brick or mortar from masonry fireplace to accommodate insert.
  • Page 9: I Nsert P Re -I Nstallation P Reparation

    12. Slide the extension draft rod through the bracket attached to the bottom of the left side hearth plate, making sure the end without the grooves is toward the stove body. Thread the coupling nut on the end closest to the stove body and then thread the coupling nut on the rod from the stove.
  • Page 10: C Himney L Iner I Nstallation

    himney iner nsTallaTion Remove the existing chimney cap and install a stainless steel liner into the chimney (if a special section has been used or drilled to attach to the insert, it must be the bottom piece). The next piece should be a dripless slip joint; followed by the rest of the chimney liner.
  • Page 11: Perating H Ints

    PeraTing inTs Burn only dry, well-seasoned wood for maxi- mum heat output. In some states it is illegal to burn wet wood or anything other than clean, dry wood products. Your stove is designed to operate with the door closed! Operate only with the door shut tightly at all times except when loading wood.
  • Page 12: Tarting And M Aintaining A F Ire

    Figure 8 Figure 9 TarTing anD ainTaining a Be sure to clean the Nickel or Gold Plated door with Windex brand cleaner and a very soft cloth to remove any fingerprints and residues prior to the first fire. 1. NEVER USE FLAMMABLE LIQUIDS TO START OR REKINDLE A SOLID FUEL FIRE!! 2.
  • Page 13: C Lean G Lass

    lean lass see mainTenance on Page 15 for glass cleaning TiPs The operator plays an important part in keeping the glass clean and free of buildups. The first and most important part the operator plays is making sure to burn only well-seasoned firewood.
  • Page 14: M Aximizing Y Our S Tove

    ’ aximizing Tove It is important to know that for high, combustion efficient, clean burns, you will need to have sufficient temperatures inside the firebox for thorough combustion. The best method for determining if you have sufficient temperatures is to watch the brick lining in your firebox.
  • Page 15: M Aintenance

    Experiment with different loading configurations to achieve longer burns. Try loading the wood from side to side and nesting it in the ashes to prevent airflow under and around the wood. Fresh wood should be loaded to the back of the firebox or to the sides.
  • Page 16: T Roubleshooting

    rouBleshooTing roBlem POOR DRAFT: Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the stoves’ draft depend solely on the natural draft of the chimney (See Drafting section on Page 4). If your stove is not drafting properly, your chimney is the problem.
  • Page 17: D O ' S And D On ' T

    ’ ’ s anD DO NOT: Install or operate this stove before reading this manual. DO NOT: Close the draft beyond the point at which the flames are completely extinguished. DO NOT: Open the stove door without fully opening the draft first. DO NOT: Burn driftwood or wood that has been in salt water.
  • Page 18: R Eplacement P Arts L Ists

    Replacement Parts Model E260 BLOWER PARTS Cat. Number Description H555 Speed Control - Wood Insert UHP Blower 201 Blower Power Cord H5559 UHP1 Cage Black H518 UHP1 Cage Gold H517 UHP1 Cage Nickel BRICKS, BLANKET, AND GASKETS H52 Firebrick (replacement - specify size) H557 Firebrick Letter A - -1/”...
  • Page 19 Replacement Parts Model C260 BLOWER PARTS Cat. No. Description H555 Speed Control - Wood Insert UHP Blower H151 Blower Power Cord H5559 UHP1 Cage Black H518 UHP1 Cage Gold H517 UHP1 Cage Nickel BRICKS, BLANKET, AND GASKETS H52 Firebrick (replacement - specify size) H557 Firebrick Letter A - -1/”...
  • Page 20: Accessories

    Accessories Model E260 TOP SURROUND PANEL (REQUIRED) Cat. No. Description 71015 7-1/2”H x 8”W Black (Total dimension when installed equals 29”x8”) 7101 10-1/2”H x 8”W Black Oversized (Total dimension when installed equals 2”x8”) BLOWER 71001 Blower Black 71002 Blower Gold 7100 Blower Nickel BLOWER SIDES...
  • Page 21 Notes...
  • Page 22: Product Reference Information

    WARRANTY Your wood appliance is covered by a limited warranty (provided with the appliance). Please read the warranty to be familiar with its coverage. Retain this manual. File it with your other documents for future refer- ence. PRODUCT REFERENCE INFORMATION We recommend that you record the following important information about your appliance.

This manual is also suitable for:

Elite e260