Lennox Hearth Products ELITE ELITE CVF Installation And Operation Manual
Lennox Hearth Products ELITE ELITE CVF Installation And Operation Manual

Lennox Hearth Products ELITE ELITE CVF Installation And Operation Manual

Catalytic vent-free wall-mounted gas fireplace signature collection

Advertisement

Quick Links

Consumer: Retain This Manual For Future Reference.
I
n the Commonwealth of Massachusetts:
• Installation must be performed by a licensed plumber or gas fitter
• See Table of Contents for location of additional Commonwealth of
Massachusetts requirements
• Hot! Do not touch! This appliance will be hot during operation and will retain heat for a while after
shutting off the appliance. Severe burns may result.
• Carefully supervise children in the same room as appliance.
• Due to high temperatures, the appliance should be located out of traffic and away from furniture or
draperies.
• Do not place clothing or other materials on or near this appliance.
• Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to
this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
• Do not build a wood fire. Do not burn wood or other material in these appliances.
• This is an unvented gas log appliance. It uses air (oxygen) from the room in which it is installed. Provisions for adequate
combustion and ventilation air must be provided. Refer to Combustion and Ventilation Air Section in this manual.
• This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where
not prohibited by local codes.
• The appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases.
• Lennox™ vent-free appliances are designed for use as a supplemental heater. They are not intended for con-
tinuous use as a primary heat source.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not light any appliance.
• Do not touch any electrical switches; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow your gas supplier's instructions.
• If your gas supplier cannot be reached, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier
INSTALLATION AND OPERATION MANUAL
Catalytic Vent-Free
Wall-Mounted Gas Fireplace
Models: Elite CVF - NG and Elite CVF - LP
P/N 850,056M Rev. NC, 07/2008
Installer: Leave This Manual With The Appliance.
Portland
US
Report No. 317-F-09-5
WARNINGS
TM
Elite™ CVF
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELITE ELITE CVF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lennox Hearth Products ELITE ELITE CVF

  • Page 1 Wall-Mounted Gas Fireplace Models: Elite CVF - NG and Elite CVF - LP Installer: Leave This Manual With The Appliance. Consumer: Retain This Manual For Future Reference. n the Commonwealth of Massachusetts: • Installation must be performed by a licensed plumber or gas fitter •...
  • Page 2: Important Safety And Warning Information

    1.0 IMPORTANT SAFETY AND WARNING INFORMATION WARNINGS If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. IMPORTANT Read and understand these instructions completely before installing or operating your unvented room heater.
  • Page 3: Table Of Contents

    CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANUFACTURED BY LENNOX HEARTH PRODUCTS. When you purchased your new gas fireplace, you joined the ranks of thousands of individuals whose answer to their home heating needs reflects their concern for efficiency and our environment. We extend our continued support to help you achieve the maximum benefit and enjoyment available from your new gas fireplace.
  • Page 4: Unpacking The Appliance

    5.0 UNPACKING THE APPLIANCE Remove the outer packaging, remove any instructions or fixing kits. Read ALL these instructions before continuing to unpack or install this appliance. Remove the remaining components from the packaging. Check that the components supplied with the packaging list on Page 3.
  • Page 5: Combustion And Ventilation Air

    8.0 COMBUSTION AND VENTILATION AIR This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The heater may be located in unusually tight construction provided the space is unconfined, or if confined, is provided with two permanent openings communicating directly with an additional room(s) of sufficient volume so that the combined volume of all connected spaces meets the criteria for an unconfined space, (National Fuel Gas Code...
  • Page 6: Site Requirements

    9.0 SITE REQUIREMENTS This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall. This appliance may be installed in any room in a home except bedrooms or bathrooms - or areas where large amounts of steam are likely to be generated.
  • Page 7: Preparing The Appliance

    10.0 PREPARING THE APPLIANCE IMPORTANT NOTE: All gas piping must be done by a licensed plumber or gas fitter and must conform to the requirements of the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition Gas connection: The heater gas inlet connection is 3/8” NPT at the regulator, located below the burner, in the center of the heater.
  • Page 8: Checking The Burner

    11.0 MOUNTING THE APPLIANCE - continued Before tightening the wall-mounting screws fully, at this stage it is recommended to check the horizontal alignment of the appliance with a spirit level, as small adjustments can still be made if necessary. When this has been checked, tighten all four fixing screws fully.
  • Page 9: Checking The Gas Connections

    14.0 CHECKING THE GAS CONNECTIONS WARNING Never use an open flame to check for leaks. Turn on gas supply and test for gas leaks using a gas leak test solution (also referred to as bubble leak solution). NOTE: using a soapy water solution (50% dish soap, 50% water) is an effective leak test solution, but it is not recommended, because the soap residue that is left on the pipes/fittings can result in corrosion over time.
  • Page 10: Spark Gap

    16.0 SPARK GAP The gap between the spark electrode and the pilot should be 1/8” to 3/16” to produce a good spark. There should be no need to adjust this (DO NOT ATTEMPT TO ADJUST THE GAP). If under any circumstances the piezo electric spark fails, the pilot cannot be lit manually.
  • Page 11: Servicing The Burner

    19.0 SERVICING (continued) 3. Remove the glass door assembly (4 screws) and clean carefully. Detach the burner front cover plate by removal of the four retaining screws. 4. Inspect the burner and the catalysts and clean if necessary with a soft brush.
  • Page 12: Catalysts

    .0 CATALYSTS WARNING Do not block the catalysts or the appliance outlet grill. Blockage may cause high carbon monoxide levels and/or breakage of the glass facia panel. WARNING Do not operate the appliance with the catalyst units removed. It is recommended that the catalysts are inspected for signs of damage and dirt during routine servicing procedures.
  • Page 13: Lighting Instructions & Turning Off Appliance

    5.0 LIGHTING INSTRUCTIONS & TURNING OFF APPLIANCE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. This appliance has a pilot which must be lit with a piezo spark igniter.
  • Page 14: Troubleshooting Guide

    6.0 TROUBLESHOOTING GUIDE PROBLEM Igniter sparks but pilot does not light Pilot lights but then goes out Igniter electrode at pilot does not spark The burner stays on for a period of time, then cuts off Pilot flame shrinks when fire is on high Fireplace smells when first lit or in use This appliance is equipped with a oxygen depletion monitoring safety device (ODS).
  • Page 15: Replacement Parts List

    7.0 REPLACEMENT PARTS - Elite CVF - NG and Elite CVF - LP Item # Cat. No. Description H7009 Glass Door Assembly H7038 Gas Valve H6060 Catalyst H6061 Pilot Assembly, Natural Gas H6999 Pilot Assembly, Propane Gas H7010 Burner Assembly, Natural Gas H7011 Burner Assembly, Propane Gas H6062...
  • Page 16: Positioning Of Field Assembled Parts

    8.0 POSITIONING OF FIELD REMOVABLE PARTS Figure 15: Exploded view of components Glass Door Removal: Remove the four (4) screws indicated, then lift door off. Figure 16 - Visual check for correct pilot flame. Burner Cover Plate Glass Door Assembly As our policy is one of continuous improvement and development, we hope therefore you will understand we must retain the right to amend details and/or specifications without prior notice.
  • Page 17: Specifications

    9.0 SPECIFICATIONS Product Reference Information Cat. No. Model Ship. Wt. H607 Elite CVF - NG 50 lb. H6073 Elite CVF - LP 50 lb. Top View 23-7/8” Front View Ship. Volume 4.3 cu. ft. 4.3 cu. ft. 6-1/4” 27-3/16” 9-3/16” 20-1/4”...
  • Page 18: Warranty

    30.0 PRODUCT REFERENCE INFORMATION WARRANTY Your gas appliance is covered by a limited warranty. Please read the warranty to be familiar with its coverage. Retain this manual. File it with your other documents for future refer- ence. PRODUCT REFERENCE INFORMATION We recommend that you record the following important information about your appliance.

This manual is also suitable for:

Elite cvf-ngElite cvf-lp

Table of Contents