Lennox Hearth Products MNTSVBE User Manual
Lennox Hearth Products MNTSVBE User Manual

Lennox Hearth Products MNTSVBE User Manual

B-vent multi-open elite series

Advertisement

This appliance may be installed in an aftermarket perma-
nently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance
is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts & New York:
• Installation must be performed by a licensed plumber or
gas fitter.
See Table of Contents for location of additional New York
& Commonwealth of Massachusetts requirements.
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
OTL Report No. 116-F-07A-5
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INSTALLATION
INSTRUCTIONS
B-VENT MULTI-OPEN
ELITE
B-VENTED GAS FIREPLACES
P/N 850,025M REV. B 01/2007
MODELS
M
l i
v i l
t l o
M
o
e d
E
B
V
S
T
N
M
E
B
V
S
E
B
V
P
F
N
M
E
B
V
P
E
B
V
C
R
N
M
E
B
V
C
E
B
V
C
L
N
M
E
B
V
C
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.
®
SERIES
s l
E
e l
r t c
n o
c i
M
T
P
M
E
B
V
S
T
N
E
E
F
P
M
E
B
V
P
F
N
E
E
R
P
M
L
P
M
o
e d
s l
B
V
C
R
N
E
B
V
C
L
N
E
1

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products MNTSVBE

  • Page 1 This appliance may be installed in an aftermarket perma- nently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Packaging ... page Introduction ... page General Information ... page Massachusetts and New York Requirements ... page Location ... page Appliance and Vent Clearances ... page Vent Termination Clearances ... page Typical Installation Sequence ... page Detailed Installation Steps ... page Step 1.
  • Page 3 S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les instruc- tions d'installation et d'utilisation qui accompagnent l'appareil. Provide adequate clearances around air open- ings and adequate accessibility clearance for service and proper operation. Never obstruct the front, back and/or side viewing surfaces of the appliance.
  • Page 4: Location

    Corner - Right (EBCR-2) **See-Through Peninsula (EBPF-2) *See-Through (EBST-2) - one side flush with a wall Figure 2 WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES. USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CARE- FULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
  • Page 5: Detailed Installation Steps

    See the page numbers references in the follow- ing steps for detailed procedures. Step 1. (page 5) Construct the appliance framing. Position the appliance within the framing and secure with nailing brackets. Step 2. (page 5) Route gas supply line to appliance location.
  • Page 6 Figure 6 FIREPLACE FRAMING SPECIFICATIONS EBVST (See-Through) inches (millimeters) Gas Line Center of gas line is 3 in. (76 mm) up from floor. (1054) *This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm) clearance between framing and unit framing spacers.
  • Page 7 FIREPLACE FRAMING SPECIFICATIONS CONTINUED EBVCL (Corner-Left) inches (millimeters) (1054) (248) (610) *This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm) clearance between framing and unit framing spacers. (The 41 in. dimension permits easier fireplace installation, if unit is installed after framing is erected.) Figure 10 EBVCR (Corner-Right)
  • Page 8: Fireplace Specifications

    FIREPLACE SPECIFICATIONS EBVST (See-Through) Figure 12 FRAMING SPACERS (13) (Top and Both Sides) DETAIL OF FINISH WALL BRACKET (610) ELECTRICAL INLETS GAS INLET (116) 3 (76) (175) LEFT SIDE VIEW FINISH WALL BRACKET (Front, back, and left edge of unit top) EBVPF (Peninsula) Figure 13 (610)
  • Page 9 FIREPLACE SPECIFICATIONS CONTINUED EBVCL (Corner-Left) Figure 14 FINISH WALL BRACKET (Front and left edge of unit top) (610) (1041) LEFT SIDE VIEW EBVCR (Corner-Right) Figure 15 DETAIL OF FRAMING SPACERS FINISH WALL BRACKET (Top, Side and Back) (13) (70) (13) (305) OUTSIDE AIR SHUTTER...
  • Page 10: Step 4. Field Wiring

    Step 4. FIELD WIRING Refer to Section A for millivolt appliances and Section B for electronic appliances. The gas valve is set in place and pre-wired at the factory on both models. A. Millivolt Wiring (See Figure 16 ) 1. Appliance-mounted ON/OFF burner control switch (rocker switch) is factory installed in the modesty panel.
  • Page 11: Step 5. Connecting Gas Line

    FIREBOX BOTTOM JUNCTION BOX OUTLET RECEPTACLE CABINET RIGHT SIDE PANEL OUTLET RECEPTACLE BOX SECURING SCREW EBST-2, EBPF-2 AND EBCL-2 OUTLET RECEPTACLE SHOWN. EBCR-2 HAS THE OUTLET RECEPTACLE LOCATED IN THE LEFT CORNER OF THE UNIT EBBAY OUTLET RECEPTACLE LOCATED IN THE REAR LEFT CORNER OF THE UNIT VIEW OF RIGHT BOTTOM CORNER OF UNIT OUTLET RECEPTACLE INSTALLATION...
  • Page 12 Valve " Nipple " Union " Close Nipple Figure 19 - GAS CONNECTION These appliances are equipped with a gas flex line for use (where permitted) in connecting the unit to the gas line. A gas flex line is provided to aid in attaching the B-vent appliance to the gas supply.
  • Page 13: Step 7. Installing Logs

    The outside air shutter should be fully open when the fireplace is in use and completely closed when the fireplace is not being used. Closing it when not in use will prevent outside cold air from entering the dwelling. Outside Air Control Lever with Stop Behind Securing Screw Outside Air Shutter in the Closed Position...
  • Page 14: Step 10. Burner Adjustment

    Step 10. BURNER ADJUSTMENTS Note - The air shutter for the burner primary air opening is factory-set. Do not adjust the factory- set position. The factory-set position is shown in Figure 25. *Air Shutter Burner Opening Venturi Tube Orifice Millivolt Shown *Note - Do Not Adjust the Factory-Set Position.
  • Page 15: Step 12. Hood Installation

    Step 12. HOOD INSTALLATION All of these appliances must have hoods installed prior to operating on all sides with glass enclosure panels. On all clean face units, slide the hoods into the slots on the lower edges of the radiant panels ( Figure 28 ). FINISHING REQUIREMENTS Wall Details Complete finished interior wall.
  • Page 16: Gas Conversion Kits

    GAS CONVERSION KITS WARNING: THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER'S IN- STRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORIZED AGENCY HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EX- ACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS...
  • Page 17 PAN BURNER FIREBOX BOTTOM BACK OF FIREPLACE BURNER POSITIONING BURNER PILOT ASSEMBLY Figure 29 Millivolt Appliances Step 4. SIT Systems - Refer to Figure 30 and the instructions provided with the kit. Using a Torx T20, remove and discard the three pres- sure regulator mounting screws.
  • Page 18 All Models Step 8. (Refer to Figure 29 ) A. Remove the orifice from the manifold and replace it with the one provided in the kit. See the following table for orifice sizes for natural and propane models . Figure 34 illustrates the orifice. B.
  • Page 19 NOTES: NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 20 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2004 by LENNOX HEARTH PRODUCTS P/N 850,025M REV.

Table of Contents