Mode A
Parameter
Values
Remarks and procedures
Refrigerator
and Freezer
Cut-in
1°F to 10°F in
increments of
1°F
Press and hold "ALARM OFF" and "HIGHER" at same time for three
seconds which will result in "OH" being displayed .
Adjustment -Press "REF TEMP" pad once to select the refrigerator
section, this will result in "REFRIGERATOR" being illuminated on
the display along with the current refrigerator cut-in value. Using the
"HIGHER and LOWER" pads make sure this value is 6°F.
Adjustment -Press "FRZ TEMP" pad once to select the freezer section,
this will result in "REFRIGERATOR" extinguishing and "FREEZER"
illuminating on the display along with the current freezer cut-in value.
Using the "HIGHER and LOWER" pads make sure the value is 7°E
Exit - Press ACTIVATE CONTROLS key once. The display will show
"PrA" to indicate control is still in Program Mode A.
Refrigerator
and Freezer
Cut-out
-10°Fto-l°F
in increments
ofl°F
Press and hold "ALARM OFF" and "LOWER" at same time for three
seconds which will result in "COH" being displayed .
Adjustment -Press "REF TEMP" pad once to select the refrigerator
section, this will result in "REFRIGERATOR" being illuminated on
the display along with the current refrigerator cut-out value. Using the
"HIGHER and LOWER" pads make sure this value is -6°F.
Adjustment -Press "FRZ TEMP" pad once to select the freezer section,
this will result in "REFRIGERATOR" extinguishing and "FREEZER"
illuminating on the display along with the current freezer cut-out value.
Using the "HIGHER and LOWER" pads make sure the value is -7°F.
Exit - Press ACTIVATE CONTROLS key once. The display will show
"PrA" to indicate control is still in Program Mode A.
Exiting Program Mode A
1. Press and hold the ACTIVATE CONTROLS key for three (3) seconds. The control will change
from Program Mode Ato Normal Mode and any changes made in Program Mode will be
saved to EEPROM.
2. If the keypad is not used for ten (10) minutes, the control will automatically change from Pro
gram Mode Ato Normal Mode and any changes made in Program Mode will not be saved to
EEPROM.