Temperature Control Operation (continued)
DegF
DegC
K-Ohms
-24
-31
565
-22
-30
531
-20
-29
499
-18
-28
469
-16
-27
441
-15
-26
415
-13
-25
391
-11
-24
368
-9
-23
347
-8
-22
327
-6
-21
308
-4
-20
291
-2
-19
274
0
-18
259
1
-17
245
3
-16
231
5
-15
218
7
-14
206
9
-13
195
Deg F
DegC
K-Ohms
10
-12
185
12
-11
175
14
-10
165
16
-9
157
18
-8
148
19
-7
141
21
-6
133
23
-5
126
25
-4
120
27
-3
114
28
-2
108
30
-1
103
32
0
97
34
1
93
36
2
88
37
3
84
39
4
80
41
5
76
43
6
72
Deg F
DegC
K-Ohms
45
7
69
46
8
65
48
9
62
50
10
59
52
11
56
54
12
34
55
13
51
57
14
49
59
15
47
61
16
44
63
17
42
64
18
41
66
19
39
68
20
37
70
21
35
72
22
34
73
23
32
75
24
31
77
25
30
Freezer temperature setting and thermistor value will determine if compressor/condenser fan and evaporator fan
switches are open or closed. Compressor/condenser fan switch must be open for 6 minutes before switch can
close again (compressor dwell time).
Refrigerator temperature setting and thermistor value will determine if fresh food fan switch is open or closed.
Cut-out and cut-in temperature values must be reached and maintained for 15 seconds before output state will
change (digital delay).
Refrigerator and freezer control calibration can be adjusted in Program Mode C.
548 non-dispenser Model code
Set in Mode C
348
548 non-dispenser offsets
Ref offset °F
Frz offset °F
-4
-5
Set in Mode B
548 non-dispenser REF / FRZ Cut-in & Cut-out table
Ref Cut-Out
°F± 1.5"
Ref Cut-in
°F±1.5°
Frz Cut-Out
°F±1.5°
Frz Cut-In
°F± 1.5°
-6
6
-7
7
Set in Mode C

Advertisement