Phase Adjustment For Multiple Arc Systems - Lincoln Electric power wave ac/dc 1000 sd Operator's Manual

Table of Contents

Advertisement

B-11
PHASE ADJUSTMENT FOR MULTIPLE
ARC SYSTEMS
Phase
• The phase relationship between the arcs helps to
minimize the magnetic interaction between adjacent
arcs. It is essentially a time offset between the
waveforms of different arcs, and is set in terms of an
angle from 0 to 360°, representing no offset to a full
period offset. The offset of each arc is set
independently with respect to the lead arc of the
system (ARC 1).
Recommendations:
• For balanced waveforms a phase relationship of 90°
should be maintained between adjacent arcs.
TABLE B.1 - PHASE RELATIONSHIP
ARC 1
ARC 2
ARC 3
Lead
Trail
2 Arc
90°
System
3 Arc
90°
System
4 Arc
90°
System
5 Arc
90°
System
6 Arc
90°
System
• For unbalanced waveforms:
– Avoid switching at same time.
– Break up long periods of unchanged polarity
relative to adjacent arcs.
PHASE RELATIONSHIP
Use Phase Relation ship to minimize arc blo w
in multip le arc systems.
(Balanced two arc syst em shown)
(PULL)
500
ARC 1
ARC 2
0
-500
BAD
Best results obtained by alternating and equalizing the duration of
magnetic for ces between adjacent arcs.
OPERATION
ARC 4
ARC 5
ARC 6
Trail
Trail
Trail
Trail
X
X
X
180°
X
X
180°
270°
X
180°
270°
180°
270°
90°
90°
180°
(PUSH/PULL )
(PUSH)
BAD
GOOD
POWER WAVE
X
X
X
X
®
AC/DC 1000
®
SD
B-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents