DSC Power632 PC1555 Instruction Manual page 8

Hide thumbs Also See for Power632 PC1555:
Table of Contents

Advertisement

Disarming the System
Disarming from an LED or Fixed Message LCD5501Z keypad:
Enter the premises through a designated Exit/Entry door. Entering by any other door will sound an
immediate alarm. As soon as the Exit/Entry door is opened, the keypad will beep to indicate that the
system should be disarmed. Go to the keypad and enter your access code. If you made an error
entering your code, re-enter the code correctly. As soon as the correct code is entered, the Armed
light will go out and the keypad will stop beeping.
The correct access code must be entered before the entry delay period expires. If a valid access
code is not entered during this time, the system will go into alarm. Your installer can change the entry
time delay.
If an alarm occurred while the system was armed, the Memory light and the zone light corresponding
to the zone that caused the alarm will flash for 30 seconds. After the 30-second period, the Memory
light and zone light will stop flashing and the panel will return to the Ready state. Pressing the [#] key
during the 30 second period will cancel the alarm memory display. To view other alarms, press [*][3].
If a trouble was detected when the panel is disarmed, the Trouble light will turn ON (See "Viewing
Trouble Conditions" on page 11 to determine the source of the trouble.) Please note that troubles will
not display while the system is in the Alarm Memory Display mode.
Disarming from an LCD Keypad:
Upon entering through a designated Exit/Entry door, the keypad will beep and the entry delay will
commence, reminding you to disarm the system. The keypad will display the following message...
Ent.ry a_ tive Enter your access code. If an error is made in entering the code, re-enter the
Enter 'r out- code code correctly. When a valid access code is entered, the keypad will stop
beeping. If there were no alarms while the panel was armed, and there are no
troubles, the display will read...
sy_t.effi Disarffied After about five seconds, the system will return to the Ready state and the display
rlO Hlarri r9eriOry will read...
Erit.et- i:nde t.o
Hrrii Sta_t.effi
L ^.:^ie^,^ r^eri^or-^u ; If there was an alarm while the system was armed, this message will be displayed.
°`Zona of Hlarri" Use the arrow (< >) keys to view which zones caused the alarm. If a zone is still in
alarm, the display will show the following message to indicate that a zone is open...
==cure Syst.eri,
E,efnre Firmirg <:
Ent.er c„de t.o Upon disarming and if a trouble is present, this message will be displayed. Use the
Hrri '=,ia_ t.ern '.> arrow (< >) keys to view which troubles are affecting the system (see "Viewing
Trouble Conditions" on page 11).
NOTE: If you return and find that an alarm has occurred while you were away, it is possible that
an intruder may still be on the premises. Go to a neighbour's house, and call the local police to
investigate.
The alarm memory is cleared each time the panel is armed. Any alarms showing are alarms that
occurred only during the last armed period.