Pre-Installation - Dean SM20 GM Installation & Operation Manual

Super marathon series gas fryers
Table of Contents

Advertisement

2.5 Pre-Installation

No structural material on the fryer should be altered or removed to accommodate
placement of the fryer under a hood. Questions? Call the Frymaster/Dean Service
Do not connect this appliance to the gas supply before reviewing all information in
General: Only licensed personnel should install any gas-fired equipment.
A.
1.
A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for
safety and ease of future service.
2.
Dean Super Marathon Series gas fryers operate on millivolts, and do not require an external
electric power supply (unless equipped with a built-in filtration system).
Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design-
B.
certified for the following installations:
1.
Commercial installation only (not for household use).
2.
Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable
legs or 5-inch (13-cm) casters;
3.
Combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches
(15-cm) rear, and equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch
(13-cm) casters.
Local building codes prohibit a fryer with its open tank of hot oil from being installed
beside an open flame of any type, including those of broilers and ranges.
SUPER MARATHON SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
DANGER
Hotline at 1-800-551-8633.
DANGER
this chapter.
DANGER
2-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sm35 gmSm40 gmSm60 gmSm80 gmSm50 gm

Table of Contents