Design Specifications; Pre-Installation - Dean Super Runner 38 Series Installation & Operation Manual

Frymaster 38 series super runner electric fryers installation & operation manual
Hide thumbs Also See for Super Runner 38 Series:
Table of Contents

Advertisement

2. IMPORTANT INFORMATION
2.1 DESCRIPTION:
Runner Series 38 electric fryers are
energy-efficient, electrically heated units,
listed by the Underwriter' s Laboratory and
manufactured to their basic performance
and application specifications.
Units are shipped completely assembled
with any accessories packed inside the
fryer vessel.
They are adjusted, tested,
and inspected at the factory prior to crating
for shipment.
rates are listed in this manual.

2.2 DESIGN SPECIFICATIONS:

a. VESSEL CONSTRUCTION: Welded,
heavy gauge steel with three heater
elements fixed inside the vessel with a
protective, chromed wire mesh crumb
screen over the elements.
tapped into front right corner of vessel
with front-controlled manual drain
valve.
b. BODY
CONSTRUCTION:
aluminized steel base with stainless
steel front and enamel sides.
frame is supported by 6" adjustable
legs or optional 6" rigid rear casters.
c. OPERATING CONTROLS: Unit is
shipped standard with a liquid filled
bulb thermostat.
control is mounted in the cabinet
behind the front door on the bottom
left side of the cabinet.
d. AUTOMATIC SAFETY FEATURE:
High temperature detection to shut-off
electric heater elements should the
controlling thermostat fail.
e. RATING PLATE: This is attached to
the
inside
Information provided includes the
The Dean Super
Sizes, weights and input
Drain
The temperature
front
door
panel.
kilowatt (KW) output of the heater
elements and electrical requirements.
THE FRYER MUST BE CONNECTED ONLY
TO THE TYPE OF ELECTRICAL SERVICE
IDENTIFIED ON THE ATTACHED RATING
PLATE.

2.3 PRE-INSTALLATION:

a. GENERAL:
should install any electrically heated
equipment.
b. CLEARANCES: The fryer area must
be
combustibles.
certified for the following installations:
1. Other than household use;
2. Non-combustible floor installation
An
The
3. Combustible construction with a
LOCAL BUILDING CODES USUALLY
PROHIBIT A FRYER WITH ITS OPEN
TANK OF HOT OIL FROM BEING
INSTALLED BESIDE AN OPEN FLAME
OF ANY TYPE, WHETHER A BROILER
OR THE OPEN BURNER OF A RANGE.
3
DANGER
A licensed electrician
kept
free
and
clear
This unit is design-
equipped with factory-supplied 6"
(15 cm) adjustable legs or optional
6" (15 cm) rigid rear casters;
minimum clearance of 6" (15 cm)
side and 6" (15 cm) rear, and
equipped with factory-supplied 6"
(15 cm) adjustable legs or 6" (15
cm) casters.