Mahlkonig Guatemala K32S Operating Instructions Manual page 9

Table of Contents

Advertisement

|
L A D E N M Ü H L E N
S H O P G R I N D E R
Defect
Cause
The grinder does
The power supply
not start.
plug is not inser-
ted.
The overload cir-
cuit breaker has
been tripped.
The motor protec-
tor was tripped.*
The pre-fuse was
tripped.
*115V / 60Hz only
Coffee Laboratory 589 Rappahannock Drive White Stone Va 22578 TEL (866) 244-1578 www.coffeelabequipment.com
Remedy
Insert the plug into the out-
let.
Check to determine wheth-
er the reset button of the
circuit breaker has jumped
out. Press the reset button
in again if appropriate. In
case of repeated tripping of
the circuit breaker, contact
your authorised customer
service centre or dealer.
Give the grinder a cooling-
off break of at least 100
minutes (para. 4).
Check the pre-fuse. Restore
the pre-fuse to its initial
state or replace it. Deter-
mine whether other con-
suming devices are also
connected to this fuse.
Defect
Cause
Grinder rotates but
Carrier breakage.
without grinding.
Metal parts on the
hopper
obstruct the inco-
ming flow of ma-
terial to be ground.
In case of other malfunctions or continued faults, please contact your
dealer or your authorised customer service centre.
Remedy
Remove the grinder casing
cover, take out the broken
pieces of the driver, insert a
new driver and then install
the grinder casing cover
again.
Clean the hopper magnet.
magnet
page 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Guatemala k22s)

Table of Contents