Wireless Device Setup and Programming
This section describes how to enroll and program wireless devices such as contacts, motion sensors and
sirens on the alarm panel.
[804][000] Enroll Wireless Devices
Once the HSM2HOST is installed and enrolled on the alarm panel, wireless devices can be enrolled using
the following method:
1. Enter Installer Programming section [804][000].
2. When prompted, either activate the device (see device installation sheet) to enroll immediately or
enter a device ID number. Do the latter to pre-enroll devices then enroll them later at the customer
site. The alarm panel determines the type of device being enrolled and presents the appropriate pro-
gramming options.
Wireless Device Options
Device Type Programming Options
Zone
Wireless Key
Siren
Repeater
3. Use the scroll keys or type in the corresponding number to select an option.
4. Scroll through the available selections, key in a number or enter text as appropriate.
5. Press [*] to accept and move to the next option.
6. Once all options are configured, the system prompts to enroll the next device.
7. Repeat the process described above until all wireless devices are enrolled.
Note: The configuration options listed above can be modified using [804][911] Modify Device.
[804][001]-[716] Wireless Device Configuration
To configure wireless devices:
1. Enter Installer Programming section [804] then select one of the following sub-sections:
001-128 – Configure Wireless Zones
l
551-566 – Configure Wireless Sirens
l
601-632 – Configure Wireless Keys
l
701-716 – Configure Wireless Keypads
l
2. Select a device to configure using the scroll keys or go directly to a specific device by entering a
hotkey.
3. Use the scroll buttons or enter a hotkey to select a configuration option for the device. See device
sheets for details.
4. Press [*] to accept and move to the next option.
5. Once all options are configured, the system returns to the base configuration menu.
6. Repeat the process described above to configure other wireless devices.
(01) Zone type
(02) Partition assignment
(03) Zone label
(01) Partition assignment
(02) User label
(01) Partition assignment
(02) Siren label
(01) Repeater label
Wireless Device Setup and Programming