Installation Of The Outdoor Unit - Technibel CSCF 208 LL Installation Instructions Manual

Hide thumbs Also See for CSCF 208 LL:
Table of Contents

Advertisement

3.1.6 - HORIZONTAL BLOWING
• Remove the cabinet (see page 4).
1 - Remove the outlet grille (1): undo the two clips (A) by turning them a quarter of a turn (using a screw driver or a coin).
2 - Remove the door (9) by pressing on the side to release the hinge pin (B).
3 - Remove the control panel (7) by taking out the two fastening screws (C).
4 - Remove the removable panel (2) by taking out the four fastening screws (D).
5 - Refit the removable panel (2) on the top and fix it with the four screws (D).
6 - Refit the control panel (7) on the front part and fix it with the two screws (C).
7 - Refit the door (9) by pressing on the side to engage the hinge pin (B) in the hole.
Refit the outlet grille (1) and lock the two clips (A) by turning them a quarter of a turn.
8 - Remove the ceiling tray held by 4 screws.
A
1
1
D
4
C
C
6

3.2 - INSTALLATION OF THE OUTDOOR UNIT

• Safety index: IP x 4.
3.2.1 - WALL MOUNTING
• Use the wall support available as an accessory (see drawing opposite):
- code K 70 U 001 T for GRF 98 L and 128 L,
- code K 60 U 035 T for GRF 188 L.
3.2.2 - FLOOR MOUNTING
• Select the location for the unit on the basis of the following criteria:
- the unit must be installed outside,
- it is necessary to make sure that the free space around the unit is provided
(see the minimum dimensions on the drawing below),
- installation must be simple and make maintenance work easy,
- the unit must be fixed on a hard base and must be protected from
risks of flooding,
- the blown air must not be directed towards surrounding windows,
- vibrations and noise must not be transmitted to a nearby building.
AVOID:
- Excessive exposure to salty air or sulfuric gas.
- Heat sources and extraction fans.
- Projections of mud (next to a roadway or path, for example).
- Areas where there is strong wind blowing against the unit's air
exhaust.
A
2
D
7
A
1
7
B
B
9
3
2
5
B
A
9
B
8
100
5
C
7
2
D
D
Wall
support
200
100
500
400
100
GB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cscf 408 llCscf 308 ll

Table of Contents