CONTENTS NAME OF PARTS AND OPERATION SELECTOR SWITCH INSTALLATION LOCATION ELECTRICAL REQUIREMENTS SAFETY INSTRUCTIONS USING THE REMOTE CONTROL UNIT REMOTE CONTROL UNIT HOW TO SET THE PRESENT TIME COOLING HEATING AUTOMATIC OPERATION DOUBLING SPEED FUNCTION DEHUMIDIFYING (DRY) FAN ONLY ADJUSTING THE FAN SPEED ECONOMY MODE HIGH POWER MODE SETTING THE TIMER...
NAME OF PARTS AND OPERATION SELECTOR SWITCH OPER TIMER STBY 1. Remote control unit. 7. OPERATION lamp: This lamp lights up during 2. Remote control sensor: Detects the room temperature operation. around the remote control unit, the air conditioner is It blinks once to announce that the remote controlsignal controlled accordingly.
Insert two AAA alkaline batteries of 1,5 V-DC making INSTALLATION LOCATION sure that point in the direction marked in the battery We recommend this air conditioner to be installed compartment.The displayed time flashes. properly by qualified installation technicians in Press the SEL TYPE button. accordance with the installation instructions provided with the unit.
REMOTE CONTROL UNIT DISPLAY Information is displayed when the remote controller is I FEEL mode is active switched on. If switched off, only the operating mode, the (remote controller sensor active) room temperature and the clock are shown Disables the temperature error that can not be Operation mode Room reached...
AUTOMATIC OPERATION HOW TO SET THE PRESENT TIME 1. Press the button ST three times. 1. Set the selector to AUTO (symbol The time indication alone flashes. the display; also the symbol remains 2. Press the SET H button until the present time hour displayed).
DEHUMIDIFYING (DRY) NOTA The fan is forced to the minimum speed and the setpoint 1. Set the button to DRY. The icon is displayed. is increased/reduced automatically by 2,5°C in cooling/ 2. Press the +/- buttons (temperature selection) to set the heating respectively.
SETTING THE 1 HOUR TIMER ADJUSTING THE AIR FLOW DIRECTION This function causes the unit to operate for one hour at the You can adjust the air flow direction using the 4 flaps of set conditions, regardless of whether the unit is on or off. the grille frame.
CARE AND CLEANING WARNING Maintenance operations must be carried out by specially trained personnel. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard.
Page 10
HOW TO REMOVE THE CONDENSATE DRAIN PAN AIR FILTER The air filter should be cleaned at least once every six months or more frequently; it depends on the real operation conditions. HOW TO REMOVE THE FILTER CONNECTORS RUBBER CORK CONDENSATE DRAIN PAN CLIPS (2) LATCH...
Trouble: the terminal does not run at all. TIPS FOR ENERGY SAVING Possible cause: DO NOT: 1. Power failure. 2. Leakage breaker tripped. Block the air intake and outlet of the unit. 3. Line voltage is too low. If they are obstructed, the unit will not work well, and 4.
Page 12
LEDS’ TABLE LEGEND LED ON = LED OFF = flashing LED (0,1 second ON, 0,1 second OFF) = flashing LED (2 seconds ON, 2 seconds OFF) = flashing LED (7 seconds ON, 7 seconds OFF) = NORMAL OPERATION STANDBY STANDBY...
Page 13
Z.I. Route départementale 28 01600 Reyrieux France Tél. 33 4 74 00 92 92 - Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...