INSTALLATION INSTRUCTIONS
CP(V) 188 - 268
CPV 188 L
CP 188 R
CPV 268 X
CP 268 R
SLIMLINE DUCTABLE SPLIT AIR CONDITIONER
February 2003
10 11 341 - GB - 05
1

Advertisement

Table of Contents
loading

Summary of Contents for Technibel CPV 188 L

  • Page 1 INSTALLATION INSTRUCTIONS CP(V) 188 - 268 CPV 188 L CP 188 R CPV 268 X CP 268 R SLIMLINE DUCTABLE SPLIT AIR CONDITIONER February 2003 10 11 341 - GB - 05...
  • Page 2: Table Of Contents

    MARKING This product marked conforms to the essential requirements of the Directives: - Low voltage no. 73/23 EEC, modified 93/68 EEC, - Electromagnetic Compatibility no. 89/336 EEC, modified 92/31 and 93/68 EEC. SUMMARY 1 - General ..................2 2 - Presentation .................. 3 3 - Positionning of the units ..............
  • Page 3: Presentation

    2 - PRESENTATION 2.1 - DESCRIPTION INDOOR UNIT - PA PA 188 C PA 268 X Materials: 1 - Blowing PA 188 R Sheet metal casing. 2 - Suction PA 268 R Polyethylene insulation M1. 3 - Electrical box Copper/aluminium evaporator. 4 - Ventilation Copper piping.
  • Page 4 OUTDOOR UNIT - GR(V) 1060 GRV 265 X GRV 180 L GR 188 R 258.5 258.5 GR 268 R Weight (kg) GRV 180 L GR 188 R GRV 265 X GR 268 R 2.3 - DIMENSIONS AND WEIGHTS OF THE ACCESSORIES OF THE PA PA 188 C / R PA 268 X / R Accessories...
  • Page 5: Positionning Of The Units

    3 - INSTALLATION OF THE UNITS 3.1 - INSTALLATION OF THE INDOOR UNIT • The appliance can be installed vertically or horizontally. 3.1.1 - RECOMMENDATIONS • Safety index: IP 20. AVOID: • Putting the unit in very damp places. • Direct exposure to sunlight or the proximity of heat sources. •...
  • Page 6: Connections

    3.2 - INSTALLATION OF THE OUTDOOR UNIT • Safety index: IP x 4. GRV 265 X 3.2.1 - WALL MOUNTING • Use the wall support (supplied as an accessory): - reference K 70 U 001 Z for GRV 180 L, GR 188 R and GR 268 R.
  • Page 7 Liquid Model B (in m) A (in m) R 407 C = 1 670 1-phase CPV 188 L 1/2" 1/4" > 2 m 25 g/extra m 1 710 3-phase CPV 268 X 5/8" 3/8"...
  • Page 8 4.3.1 - INSULATION OF PIPES • Insulate the 2 tubes separately. • Use minimum 8 mm thick polyethylene sheathing. • Pay particular attention to preventing water entering along the pipes via the hole in the wall. 4.3.2 - CONNECTION ON THE INDOOR UNIT Dia.
  • Page 9 4.4.2 - TABLES OF CURRENT Cooling only models Heat pump models UNITS on 230V/1/50HZ CP 188 R CP 268 R CPV 268 X CPV 188 L Cooling Heating Cooling Heating Nominal current 14.5 10.1 14.5 Max. current 13.5 18.6 13.2 13.5...
  • Page 10 B - FITTING Opening the box: 5 - 7 mm - Insert the screwdriver in the opening and turn it approximately 45°. - Remove the cover. Cable lead-through Main fastenings Fastening: - The base plate comprises different openings for fastening to Fastening hole the box if flush fitted or protruding.
  • Page 11 4.4.6 - OTHER POSSIBILITIES OF CONNECTION (reversible models only) A - REMOTE AMBIENT TEMPERATURE SENSOR • The control box is ready equipped with an ambient temperature sensor (marked R 26). Bare Sensor in a • In case of installation constraints, it may be necessary to off-set the sensor wall unit ambient temperature sensor.
  • Page 12: Indoor Unit Accessories

    5 - INDOOR UNIT ACCESSORIES 5.1 - FILTER WITH SPIGGOT - Code K 60 V 220 T • This accessory is mounted on the air intake (front or rear panel). • It is secured by means of 6 screws (supplied). •...
  • Page 13 CONTROL • The kit comes with the control cable 3 G 1.5 mm • Route this cable through a cable gland of the air-conditioner’s electrical box to the next terminal strip as shown in the wiring diagram in paragraph 12 (cable G ). NOTE: For the reversible models, set the remote control’s SC1 program switch on "0"...
  • Page 14 5.5 - REMOTE CONTROL (exclusively for cooling only models) 5.5.1 - PRESENTATION Manual remote control - K 60 D 016 Z S1 On/Off switch. S2 Ventilation speed selector switch. S3 Function selector switch. N (neutral) B1 Room thermostat. L (phase) Automatic remote control - K 60 D 025 Z Optional: a remote temperature sensor K 60 D 028 Z (simple) or K 60 D 033 Z (box) may be connected (see documentation supplied with the sensors).
  • Page 15: Outdoor Unit Accessories

    6 - OUTDOOR UNIT ACCESSORIES 6.1 - WALL SUPPORT for GRV 180 L, GR 188 R, GR 268 R - Code K 70 U 001 Z 1 - After making sure that the fixing system used is suitable for the wall, fix the 2 vertical brackets to the wall. Make sure that measurement A is correct.
  • Page 16: Connecting Accessories

    Unit Length Code K 70 A 02 BT • These connections include the 2 insulated refrigeration lines. CPV 188 L K 70 A 04 BT 7.2 - COMPLETE CONNECTION ASSEMBLIES CP 188 R K 70 A 08 BT 12 m K 70 A 12 BT •...
  • Page 17 8.2.2 - REMOTE CONTROL A - FRONT PANEL • Keys: 1 - Increase temperature set-point. 2 - Decrease temperature set-point. 3 - Air-conditioner operating mode selector. 4 - Ventilation operating mode selector. • LED lights: 5 - Set-point temperature. 6 - Signalling (option). 7 - Operation in heating mode.
  • Page 18 8.3.2 - OPERATING MODES • The 5 available operating modes: - Standby (indicated by yellow LED 9) - Automatic (indicated by red LED 10) - Ventilation only (indicated by red LED 11) - Cooling only (indicated by red LED 12) - Heating only (indicated by red LED 13) •...
  • Page 19 8.3.5 - ANTI-SHORT CYCLE COMPRESSOR • To avoid over-frequent starting-up of the compressor and thus increase its lifetime, a 3 minute time delay is triggered every time the compressor is activated. • If the temperature varies suddenly during this time delay to the point of calling for heating or cooling, or if the set-point is changed in the same proportions, the LED for the corresponding demand starts flashing, indicating that the anti-short cycle has been activated.
  • Page 20: Starting Up

    8.4 - STARTING THE CONTROL CHECKS TO BE CARRIED OUT • This paragraph only concerns the control. • For all measures and precautionary steps to be taken when starting up the air-conditioner, refer to § 9. The STANDBY light 9 illuminates after 20 seconds. 1 - Power-up the controller.
  • Page 21: Maintenance Instructions

    9.2 - SWITCH ON THE UNIT • Using the isolation and protection device. 9.3 - START THE UNIT • Using the indoor unit's control panel (see paragraph 8.4 for reversible models). 9.4 - VENTILATION OF OUTDOOR UNIT • All all-season usage, the GRV 180 L is equipped with a condensation pressure control system as standard Ventilation motor speed varies according to the outside air temperature and the temperature of the outdoor exchanger.
  • Page 22: Pressure Curves

    11 - PRESSURE CURVES 11.1 - R 22 MODELS 11.1.1 - COOLING MODE HIGH PRESSURE LOW PRESSURE CP 188 R ° Out. temp. = 43 ° Out. temp. = 35 ° Out. temp. = 19 ° Out. temp. = 43 °...
  • Page 23 ° Outside wet bulb temperature ( Outside wet bulb temperature ( 11.2 - R 407 C MODELS (cooling only) HIGH PRESSURE LOW PRESSURE CPV 188 L ° Out. temp. = 43 ° Out. temp. = 35 ° Out. temp. = 19 °...
  • Page 24: Electrical Connection Diagrams

    12 - ELECTRICAL CONNECTION DIAGRAMS 230V/1/50Hz to CONNECTION CPV 188 L Alimentation kit chauffage Standard Accessoire Power heater kit Monter le pont livr avec le kit. Standard Accessory Connect the bridge with the wire included in the kit. Alimentazione kit riscaldamento...
  • Page 25 230V/1/50Hz to CONNECTION CPV 268 X Alimentation kit chauffage Alimentation g n rale Standard Accessoire Power heater kit Monter le pont livr avec le kit. Mains supply Standard Accessory Alimentazione kit riscaldamento Connect the bridge with the wire included in the kit. Alimentazione generale Standard Accessorio...
  • Page 26 230V/1/50Hz to CONNECTION CP 188 R / 268 R Standard Accessoire Standard Accessory Alimentation kit chauffage Standard Accessorio Power heater kit Estándar Accesorio Alimentazione kit riscaldamento Standard Zubehör Alimentación kit de calefacción Stromversorgung der Heizung 230 V / 1 / 50 Hz Bleu Marron Vert/Jaune...
  • Page 27 400V/3N/50Hz to CONNECTION CP 268 R Standard Accessoire Standard Accessory Alimentation kit chauffage Standard Accessorio Power heater kit Estándar Accesorio Alimentazione kit riscaldamento Standard Zubehör Alimentación kit de calefacción Stromversorgung der Heizung 400 V / 3 / 50 Hz Bleu Marron Vert/Jaune Blue...
  • Page 28: Wiring Diagrams

    13 - WIRING DIAGRAMS SYMBOLS OF COMPONENTS Control board Heating contactor Anti-frost thermostat Phase sequence relay Thermal safety Electronic card Thermal safety POW-CL Filter Fan capacitor Fan relay Compressor capacitor Control circuit circuit-breaker Filtration capacitor Crankcase heater Starting capacitor Electric heater Starting capacitor Electric heater Crankcase heater...
  • Page 29 PA 188 C / PA 268 X - 230/1/50 10 05 665 - 00 ALIMENTATION 230V/1/50 POWER SUPPLY 230V/1/50 4A 250V 5x20 N (PA 268 ) G (PA 188 ) G (PA 268 ) M (PA 188) Commande COMPRESSEUR / COMPRESSOR Control Commande CHAUFFAGE / HEATING Control VENTILATION FAN MOTOR...
  • Page 30 GRV 180 L - 230/1/50 Connecteur 2P (vert) Connector 2P (green) 5 4 3 GRV 180 L - 400/3N/50 (COIL) R1 R3 THC2 S1 S2 THC1 Connecteur 2P (bleu) Connector 2P (blue) (AIR) THR2 THR1 U 14 Connecteur 2P (jaune) Connector 2P (yellow) Connecteur 2P (blanc) Connector 2P (white)
  • Page 31 GRV 265 X - 230/1/50 10 05 457 - 06 Alimentation 230/1/50 Power supply 230/1/50 Raccordement PA Connection PA 10 05 458 - 03 GRV 265 X - 400/3N/50 Alimentation 400/3N/50 Power supply 400/3N/50 Raccordement PA Connection PA...
  • Page 32 GR 188 R - 230/1/50 10 05 690 - 01 (01-8) (01-6) (01-12) (01-16) (01-12) (01-16) (01-16 )
  • Page 33 GR 268 R - 230/1/50 10 05 662 - 00 (01-6) (01-8) Raccordement compresseur Compressor connection (01-12) (01-16) (01-12) (01-16) (01-16 ) 10 05 663 - 00 GR 268 R - 400/3N/50 (01-6) (01-8) Raccordement compresseur Compressor connection (01-12) (01-16) (01-12) (01-16) (01-16 )
  • Page 34 KIT CHAUFFAGE ELECTRIQUE / ELECTRIC HEATING KIT - 3 kW - 230/1/50 - 400/3/50 10 05 678 - 00 Alimentation / Power supply (01-9) (01-16) (01-16) (01-16) KIT CHAUFFAGE ELECTRIQUE / ELECTRIC HEATING KIT - 6 kW - 230/1/50 - 400/3/50 10 05 667 - 00 Alimentation / Power supply (01-9)
  • Page 35 Due to our policy of continuous development, our products are liable to modification without notice. R.D. 28 Reyrieux BP 131 01601 Trévoux CEDEX France Phone 33 4 74 00 92 92 - Fax 33 4 74 00 42 00 R.C.S. Bourg-en-Bresse B 759 200 728...