5 - INDOOR UNIT ACCESSORIES
5.1 - WALL SUPPORT
• Fix the support to the wall using the screws and plugs
supplied.
• Level it using the M6 hex. head screws (item A).
Code
Unit
accessory
TAF 208 L
K 60 U 023 Z
TAF 308 L
K 60 U 024 Z
TAF 408 L
K 60 U 028 Z
5.2 - ELECTRIC HEATING
TAF 208 L, 308 L = 2 kW: code K 60 C 852 Z
3 kW: code K 60 C 853 Z
TAF 408 L
= 2 kW: code K 60 C 862 Z
3 kW: code K 60 C 863 Z
• See installation instructions supplied with the accessory.
5.3 - REMOTE CONTROL
5.3.1 - MONTAGE / INSTALLATION
• See the main characteristics in the Technical Instructions.
• Consult the "Installation instructions" supplied with the control.
• The unit is connected using 0.75 mm
The cables used must comply with the insulation requirements for the voltage used (230 V).
This information relates above all to the sensor input of the automatic control connected to the 230 V supply.
• The temperature adjustment range can be limited by means of the mechanical limit stops located on the control knob.
• Wall mounting:
- Secure the unit at a height of approximately 1.5 m from the floor in a location representative of normal convection
currents, while avoiding:
- wall which are poorly insulated or liable to vibrate,
- the proximity of parasitic heat sources (sunshine, heating appliances, lamps, fireplaces, televisions, etc.),
- currents of air from doors or windows,
- sheltered locations such as shelves or behind curtains,
- near electrical outlets.
- For manual control 70250076, check and modify as required the ventilation selection jumper connection SR depending
on the appliance (see below).
- For the K 60 D 025 Z automatic control, if necessary, adjust the neutral zone using the potentiometer located inside the
control.
• Do not install in a local where there is a risk of condensation or water projection (max. relative humidity: 95%).
A
B
870
850
1,060 1,040
1,180 1,160
2
cable (minimum) (1.5 mm
9
2
max.).
GB
13
A