28 CONNECTING THE FLUE TO THE BOILER
1. Measure 68mm from the cut end of the flue assembly and mark a line on the
flue.
2. Fit the flue connector over the end of the flue and align the end of the
connector with the marked line.
3. Ensure the 'V' cutout on the flue connector is aligned with the top of the turret
(use label as a guide).
4. Mark the 3 fixing screw holes and drill the three holes with a 3.2 (
Do not drill through the inner flue pipe.
5. Retain the connector with the 3 screws provided.
6. Adhere the 70mm wide x 20mm deep foam strip (found in
the hardware pack box) to the flue assembly tube to
provide an inner seal to the hole cut in the wall.
7. Insert the flue assembly through the prepared hole in the
wall.
8. Remove the top outlet blanking plate or boiler top panel
to facilitate turret fitting. To ensure a positive flue seal is
confirmed it may be necessary to remove the worktop
or adjacent cupboard to view the joint.
9. Fit the sealing gasket and push the flue turret into
the top of the boiler flue sealing ring and retain with
the 4 screws provided.
10. Smear lubricant (to be found in hardware
pack) over both inner flue duct seal and outer
air duct seal and locate the flue onto the
turret ensuring the 2 bayonet fixings on
the flue connector (B) engage to the
lugs on the turret (A).
11. Replace the top outlet blanking
plate.
12. Flues over 1 metre long.
Fix the flue support bracket
to the wall, using the wall
plug and wood screw.
mexico HE -
Installation & Servicing
INSTALLATION
/
") dia drill.
1
8
10
A
9
Flue Outlet
9
3
4
B
2
1
68mm
5
Top outlet
blanking plate
Sealing Gasket
Label
7
6
23