21 MOUNTING THE BOILER ONTO THE PRE-PIPING FRAME
NOTE. USE THE BOILER PACKAGING SLEEVE TO PROTECT THE
FLOOR.
1. Remove the two screws retaining the lower front panel and remove
the panel
2. Remove the two screws retaining the upper front panel.
3. Lift the upper front panel and remove. If the optional extra
concealment panel kit is to be fitted to either left or right hand side
panel, it must NOW be fitted (refer to separate instructions provided
with kit).
4. At this stage fit the flue assembly and turret (see Frame 28 or 33)
and in the case of rear flue fit the optional flue finishing kit, refer to
Frame 27, if required. Remove the top panel to facilitate turret
fitting.
5. Fit the sealing washers to the water and gas connections.
6. If the condensate pump is to be used, it must now be fitted (If not to be
fitted go to No. 7)
a. Fit the condensate pump fixing slots over the two screw heads. The
screws position the pump but cannot be tightened.
b. Prepare to route the condensate pump cable, the mains cable
and the remote user controls wiring (if required) up the rear of
the boiler and through the grommet to be found at the top left of
the boiler.
c. Using the rubber connecting joint, provide a plastic outlet pipe
from the pump outlet connection, to a suitable drain point
connection taking care to route the pipework such that it will not foul
the boiler when fitted. Refer to Frame 18.
d. Make up the inlet plastic pipe connection to the following drawing and
fit to the 'S' trap flexible hose connection.
60mm (HE15, HE18, HE24)
190mm (HE30, HE36)
6d
8
7. Remove the four screws retaining the boiler to the
wooden packaging base and using the packaging
sleeve to protect the floor, slide the boiler onto the pre-
piping frame ensuring the mains cable and the
condensate pump cable (if fitted) is routed through the
grommet at the top left of the boiler.
8. Screw the boiler frame to the floor through the 2 slots in
the front of the boiler runners.
20
INSTALLATION
Flexible hose
from 'S' trap
Outlet pipe
6a
connecting
9. Connect the gas and water union connections ensuring the
10. Connect the condensate pump inlet ensuring the pipe is
11. Wire the mains connection, the condensate pump
Sealing Gasket
4
3
2
mxhe7610
1
6d
6c
6d
Inlet pipe
from 'S' trap
Rubber
joint
sealing washers are in place.
pushed to bottom of the pump housing. If no pump is fitted
connect the S trap flexible hose to the previously installed
condensate drain pipe. Refer to Frame 13.
connection (if fitted) and the remote user control (if fitted).
Refer to Frame 35.