Welcome Thank you for purchasing our IP camera! This quick start guide is designed to be a reference tool for your system. Please keep this start guide well for future reference. Please open the accessory bag to check the items one by one in accordance with the list below. Contact your local retailer ASAP if something is missing or damaged in the bag.
Page 3
Please shut down the device and then unplug the power cable before you begin daily maintenance work. Do not touch the CCD (CMOS) optic component. You can use the blower to clean the dust on the lens surface. Always use the dry soft cloth to clean the device. If there is too much dust, please use the water to dilute the mild detergent first and then use it to clean the device.
1 Framework 1.1 MD9M Data Converter Cable You can refer to the following figure for MD9M data converter cable information. See Figure 1-1 Figure 1-1 Please refer to the following sheet for detailed information. Port Name Function Connection Note Video output Output analog video signal.
Port Name Cable Name Note Color Alarm output port. It is to output the alarm signal to the alarm device. White ALARM_NO NO: normal open alarm output port. It works with the ALARM_COM port. It is to restore factory default setup. When the device is working properly, please Blue RESET...
2 Installation This series IPC can be put on the table to realize surveillance. Or you can use the bracket or the in-ceiling installation to realize the hang function. Please refer to the steps listed below. 2.1 Device Installation Step 1 Use the inner hexagonal wrench (provided) to loose the three inner hexagon screws in the dome cover and then open the cover.
Page 9
Figure 2-2 Step 3 Draw out the cable exit and four screw holes in the installation position according to the device pedestal. Dig the four plastic expansion bolt hole and cable exit. Insert the four plastic expansion bolts into the screw holes Step 4 Adjust the camera pedestal to the proper position and then draw the cable through the cable exit you just dug in the ceiling (wall).
Page 10
Figure 2-3 Step 6 Adjust the X-Y-Z axis module to turn the device to the proper monitor angle. Please follow the steps listed below to adjust. Slightly loose the screws at the two sides of the X-Y-Z module manually, you can adjust the module tilt rotation angle (15°~90°).
Figure 2-5 2.2 SD Card Installation Important Before you install the SD card, please unplug he power cable to shut down the device! First, please refer to the step1 in the chapter 2.1 to open the device. Second, please adjust the proper position to install the SD card. Last, please refer to the step 7 in the chapter 2.1 to complete the installation.
2.3 Lens Adjustment Step 1 Slightly loose the screw B manually and then turn the screw B slowly. Adjust the lens focus distance to the proper position according to the monitor video. See Figure 2-7. Step 2 Use the flat screwdriver to loose the screw A slightly and then turn the Screw A slowly. Adjust the lens focus to get the clear video and then use the flat screwdriver to secure the screw firmly.
3 Quick Configuration Tool 3.1 Overview Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device. Please note the tool only applies to the IP addresses in the same segment. 3.2 Operation Double click the “ConfigTools.exe”icon, you can see an interface is shown as in Figure 3-1.
Page 14
Figure 3-2 Select the “Open Device Web” item; you can go to the corresponding web login interface. See Figure 3-3. Figure 3-3 If you want to modify the device IP address without logging in the device web interface, you can go to the configuration tool main interface to set.
Page 15
Figure 3-5 For detailed information and operation instruction of the quick configuration tool, please refer to the Quick Configuration Tool User’s Manual included in the resources CD.
4 Web Operation This series IPC product support the Web access and management via PC. Web includes several modules: monitor channel list, record search, alarm setup, system configuration, PTZ control, monitor window and etc. IP camera factory default setup: IP address: 192.168.1.108. User name: admin Password: admin 4.1 Network Connection...
Page 17
Figure 4-2 After installation, the interface is shown as below. See Figure 4-3. Please input your user name and password. Default factory name is admin and password is admin. Note: For security reasons, please modify your password after you first login. Figure 4-3 After you logged in, you can see the main window.
Page 18
Figure 4-4 Please refer to the HD IR Vandal Proof IP Dome Camera Web Operation Manual included in the resource CD for detailed operation instruction.