Sony PWS-4400 Operation Manual page 28

Multi-channel recorder multi port av storage unit
Hide thumbs Also See for PWS-4400:
Table of Contents

Advertisement

User Specified Name
Sets the 4-character prefix for the names of recorded files.
Enter an arbitrary string in the text box or select a prefix
from the drop-down list.
TC
Makes time code settings.
TCG Source
Selects the source signal for synchronizing the internal
time code generator.
• Internal-Preset
• External-LTC
• SDI-LTC
• SDI-VITC
• Master TC
REGENE Source
Selects the signal to regenerate when the time code
generator is in regenerate mode or in automatic editing
mode.
• TC&UB: Regenerates both the time code signal and user
bit signal.
• TC Only: Regenerates the time code signal only.
• UB Only: Regenerates the user bit signal only.
RUN Mode
Sets the running mode of the time code generator.
• Free Run: The time code advances when the power is on
regardless of the unit's operating mode.
• Rec Run: The time code advances during recording only.
DF Mode
Sets the drop frame mode of the time code generator or
timer counter.
• NDF
• DF
Note
This setting is valid only when [TCG Source] is set to
"Internal-Preset" and the frame frequency is 29.97 Hz.
TC Out Select
Sets the output time code from the TIME CODE OUT
connector when recording.
• Regene
• Through
Timer Select
Selects the time data to display.
• TC
• UB
• TM1
• TM2
Timer Set
Displays the time counter.
28
Port Screen
To change the counter, enter a value and click the [Set]
button. Clicking the [Reset] button resets the counter.
Note
Displayed only when [Timer Select] is set to TC, UB, or
TM1.
Character
Character On/Off
Selects whether to display superimposed character
information, such as the time code, on the monitor signal.
Character Size
Sets the display size of character information.
• Small
• Medium
Vertical Position
Sets the vertical display position of character information.
• 0 (top) to 22 to 255
Horizontal Position
Sets the horizontal display position of character
information.
• 0 (left) to 128 to 255
Character Info.
Sets the character information content if [Character On/
Off] is set to "On."
• Timedata Only: Timer counter only
• Timedata & TM1: Timer counter and TM1
• Timedata & TM2: Timer counter and TM2
• Timedata & UB: Timer counter and user bits
• Timedata & Status: Timer counter and operating status
• Timedata & Audio: Timer counter and audio level
Background
Sets the character information background.
• Outline: White characters with black outlines
• Translucent: White characters on a gray transparent
background.
• without BG: White characters with no background
• with BG: White characters on a black background
Sub Status
Sets additional information displayed with the character
information.
• Off: Displays no additional information.
• File Name: Displays the file name.
Warning Display
Sets whether to display a flashing warning message on the
second line of character information when [Character
Info.] is set to an item other than "Timedata Only".
• Off
• On