GTO Pro SL-1000 Installation Manual
Hide thumbs Also See for Pro SL-1000:

Advertisement

Safety Edge
Chain Bracket
Chain
READ ALL INSTRUCTIONS COMPLETELY
and use; failure to do so may result in serious injury or death.
• This unit must only be installed by an experienced technician!
• Operator power must be disconnected before servicing!
• This gate operator produces a high level of force. Stay clear of the unit
while it is operating and exercise caution at all times.
This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as
established and made effective March 1, 2000, by Underwriters Laboratories Inc.
DO NOT I
Telephone (800) 543-GATE or (850) 575-0176 • Fax (850) 575-8912 • www.gtoinc.com
RB270
rev - 09/25/01
AUTOMATIC GATE OPERATOR
F
OR
I
M
NSTALLATION
ANUAL FOR THE
Safety Edge
(REQUIRED)
(REQUIRED)
!
WARNING
Moving Gate Can Cause
Injury Or Death
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or
play in gate area.
3. This gate is for vehicles only. Pedestrians
must use a separate entrance.
Roller Guard
(REQUIRED)
T
O
NSTALL
HIS
PERATOR
3121 Hartsfield Road • Tallahassee, Florida, USA 32303
V
S
G
EHICULAR
LIDE
P
ROFESSIONAL
Roller Guard
(REQUIRED)
Chain Bracket
PRO-SL-2000
Operator
Use PVC Conduit
(not included)
for power cables.
W
!
ARNING
before attempting installation
W
S
E
ITHOUT
AFETY
ATES
I
NSTALLER
Safety Edge
(REQUIRED)
®
CAUTION
AUTOMATIC GATE
STAND CLEAR
1-800-543-GATE
Run 1000' (max.) of low
voltage wire to control
box from transformer
(wire not included).
R
G
DGES AND
OLLER
UARDS
¨
+
5
Receiver
(cable in separate
conduit)
120 Volt Indoor
Transformer
(Surge Protector
not supplied)
Roller Guard
(REQUIRED)
!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pro SL-1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for GTO Pro SL-1000

  • Page 1 ¨ AUTOMATIC GATE OPERATOR EHICULAR LIDE ATES NSTALLATION ANUAL FOR THE ROFESSIONAL NSTALLER Roller Guard Safety Edge (REQUIRED) (REQUIRED) Receiver Safety Edge Safety Edge (cable in separate (REQUIRED) conduit) (REQUIRED) WARNING 120 Volt Indoor Moving Gate Can Cause Injury Or Death Transformer 1.
  • Page 2 GTO PRO SL-1000 and SL-2000 series automatic gate operators are intended for use with vehicular slide gates. These operators can be used in Class I, Cass II and Class III applications. VEHICULAR GATE OPERATOR CLASS CATEGORIES Residential Vehicular Gate Operator-Class I: A vehicular gate operator (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith.
  • Page 3: Table Of Contents

    ABLE OF ONTENTS Gate Operator Class Categories -------------------------------------------------------- inside cover Important Safety Instructions ----------------------------------------------------------- page 1 Important Safety Instructions for the System Designer ---------------------------- page 2 Important Safety Instructions for the Installer -------------------------------------- page 2 Secondary means of Protection Against Entrapment ------------------------------- page 4 Important Safety Instructions for the Consumer/End User ------------------------ page 5 Warning Labels and Signs ------------------------------------------------------------- page 7 Technical Specifications for SL-1000 --------------------------------------------------- page 9...
  • Page 4: Important Safety Instructions

    Because GTO automatic gate operators are only part of a total gate operating system, it is the responsibility of the designer, installer, and purchaser to ensure the total system is safe for its intended use. Bypassing safety devices or neglecting to use safety devices with the gate operator is NOT acceptable.
  • Page 5: Important Safety Instructions For The System Designer

    IMPORTANT SAFETY INSTRUCTIONS FOR THE YSTEM ESIGNER WARNING: To reduce the risk of injury or death: READ AND FOLLOW ALL INSTRUCTIONS. This operator is intended for use only vehicular gates. Pedestrians must be supplied with a separate walk- through gate (see Entrapment Protection on page 6). When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS Secure outdoor or easily accessed gate operator controls in order to prohibit unauthorized use of the gate. III. After Installation Review ALL safety instructions with the consumer/end user and explain the basic operation and safety systems of the entire gate operator system, including disconnecting the chain for manual gate operation. Inform the consumer/end user that servicing of the operator must only be done by an experienced technician.
  • Page 7: Secondary Means Of Protection Against Entrapment

    GTO gate operators utilize Type A, an inherent entrapment sensing system, as the primary type of entrapment protection. The GTO/PRO SL-1000/2000 and GTO/PRO SL-1000B/2000B gate operators have provisions for the connection of Type B1 and B2 protection to be used as the secondary type of entrapment protection.
  • Page 8: Important Safety Instructions For The Consumer/End User

    It is your responsibility to make sure that the installer posted warning signs on both sides of your gate. If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact your installer or GTO for replacements. Verify that electric safety edge sensors (or photoelectric sensors) have been installed (see page 6). These safety devices should be tested monthly.
  • Page 9 For this reason, safety devices such as safety edges MUST be installed. Furthermore, a walk-through gate must be installed if pedestrian traffic is expected near the gate. We recommend the GTO Bulldog Pedestrian Gate Lock (see accessory catalog) for controlled access.
  • Page 10: Warning Labels And Signs

    1. Lift quick release pins UP , then pull them OUT of chain brackets. of control box 2. Lay chain down and manually slide gate to desired position. GTO, Inc. Tallahassee, Florida USA RB2001 Series Conforms to UL 325 STANDARDS Certified to CAN/CSA-C22.2 No.247-92...
  • Page 11 IMPORTANT SAFETY INSTRUCTIONS Continued from page 7 These warning labels should be found at the locations specified below. If any of them are missing, immediately contact your installer for replacements. WARNING • Fingers, hands, and loose clothing may be dragged into chain sprockets. WARNING •...
  • Page 12: Technical Specifications For Sl-1000

    • The PRO SL-1000 system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable battery. • Battery charge for PRO SL-1000 is maintained by a 18 Vac (40 VA) transformer rectified to 14.5 Vdc through the GTO Control Board. Two (2) blade-style control board fuses rated for 15 A.
  • Page 13: Technical Specifications For Sl-2000

    • The PRO SL-2000 system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable battery. • Battery charge for PRO SL-2000 is maintained by a 18 Vac (40 VA) transformer rectified to 14.5 Vdc through the GTO Control Board. Two (2) blade-style control board fuses rated for 20 A.
  • Page 14: Parts Identification (Single Gate Operator)

    Control Board and Battery Operator Housing Receiver 32’ Drive Chain 18 Vac Transformer (2) Chain Brackets GTO Transmitter (2) 2” square x 48” long legs ”-20 x ” Screws ” Lock Washers (2) Chain Master Links ” Serrated Nuts ” Nuts (2) Quick Release Pins ”...
  • Page 15: Single Gate Operator Installation

    The diagram below shows a single slide gate installation with recommended safety features. The operator must be installed on the inside of the gate. GTO requires using safety edges and roller guards to help reduce the possibility of bodily injury.
  • Page 16: Suggested Conduit & Wiring And Mounting The Legs

    ECOMMENDED IRING AND SE OF ONDUIT Run the low voltage wire and receiver wire through PVC conduit into the slider unit to protect it from lawn mowers, weed eaters, grazing animals, etc. PVC conduit should be used for accessory wires such as loop detectors, key pads, card readers or any other entry device.
  • Page 17: Determining The Mounting Position And Mounting The Operator

    ETERMINING OUNTING OSITION AND OUNTING PERATOR Illustration B Install chain brackets at each end of the gate on the inside (operator side) of the gate (see Overview Illustration, page. 11). Position the tops of chain brackets no more than 6” above String the bottom corners of the gate frame and secure with U-bolts Quick Release Pin...
  • Page 18: Installing The Chain

    NSTALLING HAIN After the concrete has hardened, remove the string Chain Bracket Illustration F from the quick release pins. Attach the chain to one quick release pin with a master link (see Illustration F). Run the chain through the chain sprockets (see Quick Release Pin Illustration G).
  • Page 19: Powering The System

    NOTE: Cycles shown are for single gate, dual gates will get approximately half as many cycles. 1) The MNC for the GTO/PRO SL-2000 is roughly comparable to most AC powered operators, and the transformer provided with this operator should handle most high traffic situations. If the battery does not seem to be able to provide the constant charge required for your application, the addition of the GTO/PRO 40 Amp Hour Battery Kit (see Accessoy Catalog) should provide ample power to handle any situation.
  • Page 20 6) The MNC for dual gate applications will be about 50% of those for a single gate. IMPORTANT: • The GTO transformer is intended for indoor use. If the transformer can only be plugged into an outside electrical outlet, a weatherproof housing or cover (available at electrical supply stores) must be used.
  • Page 21 NOTE: Pull approximately 1 foot of extra wire to accommodate terminal connections. To maintain adequate charging power, use appropriate gauge, stranded, direct burial wire (see Accessory Catalog). Do not use telephone wire or any solid core wire because it will not provide adequate current. Never splice wires together. GTO T NSTALLATION OF THE RANSFORMER...
  • Page 22 GTO T NSTALLATION OF THE RANSFORMER Illustration K Strip " off the ends of the low voltage wire and Wrong Wrong Correct twist tightly. These wire ends will be attached to the control board at the 18VAC terminals located on the POWER IN terminal block (see Illustration L).
  • Page 23: Control Board Settings

    The four DIP switches on the control board match the operator with the type of gate on which it is mounted. For example, gates may open right to left or left to right. Prior to packaging, the GTO/PRO Sl-1000 and SL- 2000 series control board was configured for a single slide gate that opens right to left.
  • Page 24: Potentiometers

    All three potentiometers were set to minimum at the factory. The OBSTRUCT SENS. potentiometer MUST be adjusted above the factory setting for your GTO/PRO SL-2000 series operator to function properly. If the potentiometer is left at MIN, your gate operator may "obstruct"...
  • Page 25: Connecting The Receiver To The Control Board

    RANSMITTER All GTO transmitters are set to a standard code at the factory and are ready to activate the automatic gate operator. For safety and security, however, we strongly recommend that the factory setting be replaced with a personal code.
  • Page 26: Mounting The Receiver

    Consider the following when mounting the receiver: • Receiver cable length is 20 feet (receivers with a longer cable are available as special order items; Call the GTO Sales Department). NEVER splice receiver cable! • Run the cable through PVC conduit to protect it from damage.
  • Page 27: Adjusting The Limit Switches

    DJUSTING IMIT WITCHES After the operator is installed, adjust the open and closed position limit switches as needed. The limit switches determine how far the gate travels to open and to close. Illustration M Adjust the limit switches using the limit nuts. Lift limit switch plate to adjust limit nuts (see Illustration Limit Switch Plate The open and closed position switches will be reversed...
  • Page 28: Connecting Safety Devices

    AFETY EVICES The GTO/PRO SL-1000 and SL-2000 series operators are equipped with built-in obstruction sensitivity. These operators are designed to stop and reverse the gate for 2 seconds when it comes in contact with an obstruction. However, obstruction sensitivity, even when properly adjusted, may not be sensitive enough to prevent bodily injury.
  • Page 29 Although GTO strongly recommends the use of safety devices, we do not endorse any specific brand names. Below is a list of some products compatable with GTO operators systems, some of which require their own power supply. Check with the individual manufacturer for specific power needs.
  • Page 30: Connecting Accessories

    ONNECTING CCESSORIES Make sure the control box power switch is OFF before connecting accessories. The ACCESSORY terminal block is the connection point for accessories such as push buttons, safety loops, intercoms, etc. The ACCESSORY terminal marked GRN (green) is the common ground for all accessories. GRN is paired with the terminals shown below when connecting accessories to the control board.
  • Page 31 IMPORTANT: Hang the two (2) GTO Warning Signs (provided) on both sides of the gate before operating. Make sure all warning signs and labels are in place. Make...
  • Page 32: Maintenance & Troubleshooting

    AINTENANCE The GTO Slide Gate Operator is designed for minimum maintenance. However, for optimum performance and safety, the following maintenance procedures should be taken: Having a well maintained gate will ensure that the operator runs smoothly and safely. Make sure gate is hung level and plumb.
  • Page 33 ROUBLE HOOTING UIDE Maintenance: • On all gates weighing 250 lb. or more, routinely grease the ball bearing rollers at least 4 times a year; grease more frequently if the gates are near a coastal area. • Keep a few mothballs in the control box to discourage insects from entering it and damaging the control board.
  • Page 34 12 Vdc 90 rpm with case hardened gears. The motor current range is 2.5 to 10 A if the gate is in good working order. Receiver: 5 Vdc / digital communication. ONLY GTO receivers can be connected to these terminals. Control board: Microprocessor driven.
  • Page 35: Warranty And Repair Information

    ARRANTY AND EPAIR ERVICE If the GTO gate operator system is not operating properly and you have not been able to solve the problem, please follow the steps below: Check the Trouble Shooting Guide (page 29). Call your installer. If you still cannot solve the problem, call the GTO Service Department at (850) 575-0176.
  • Page 36: Dual Gate System Installation

    INSTRUCTIONS FOR THE INSTALLATION OF A DUAL GATE SYSTEM ® AUTOMATIC GATE OPERATORS USE THE GTO/PRO SL-2200 WITH THE GTO/PRO 2000 FOR DUAL GATES...
  • Page 37 YSTEM NSTALLATION Install the second gate operator in the same manner as the Single gate operator starting on page 12 of this manual. The second gate preparation and wiring of the second (auxiliary) operator follow on the next two pages. Once the second gate operator is installed, Set the DIP switches for DUAL gates and the order in which the gates open (“sequencing”).
  • Page 38: Preparing The Gates

    REPARING THE ATES Install PVC conduit (not included) needed for power cables and low voltage wiring – see illustration below. The PRO SL-1200 and Sl-2200 power cable and safety edge (required) wiring should be run through PVC conduit underneath the driveway. If you cut the driveway be sure to reseal it after all wiring is installed. Roller Guard Safety Edge (REQUIRED)
  • Page 39: Wiring The Second Operator

    Lock Nut Sealing Nut Step 1: With the PRO SL-1000 or SL-2000 control box open, use a screw driver to punch out the round knockout hole located Lock Nut on the bottom next to the First Operator power cable. Install the strain relief for the Second Operator power cable.
  • Page 40: Setting The Control Board For Dual Gate Installations

    ETTING THE ONTROL OARD FOR NSTALLATIONS DIP S WITCHES The Control Board DIP switches must be set to accommodate your particular type of installation. Since the SNGL / DUAL, SEQ1, and SEQ2 DIP switches are used by dual gate operator systems, they will be discussed in the following steps.
  • Page 41 FIRST OPERATOR OPENS FIRST, OBSTRUCT SECOND OPERATOR CLOSES FIRST SENS. SEQ1 = OFF SEQ2 = ON PULL/PUSH SNGL/DUAL SEQ1 If SEQ1 is set to OFF, and SEQ2 is set to ON, the SEQ2 LEARN FIRST OPERATOR will open first, and the SECOND OPERATOR will close first (see illustration).
  • Page 42: Accessory Catalog

    Can be used with the GTO Digital Keypad (F300). GTO NEMA Box (FM317) GTO's NEMA 4X rated weatherproof box is large enough (14" W x 6" D x 16" H) to accommodate all add-on items necessary for custom gate operator installations. It is made of fire retardant ABS plastic and comes with a heavy duty 14 gauge steel backing plate for mounting accessories.
  • Page 43 Particularly suited for remote installations, the solar panel comes with tubular steel support, mounting clips, wire connectors, and 8 ft. of low voltage wire (see Low Voltage Wire for longer wire). All GTO low volatge operators are pre-wired for solar panels. Installation in some regions of the world will require multiple panels for adequate charging power.
  • Page 44 The AWQ400: Receiver with a 100 ft. cable. Standard Replacement Power Cables for Gate Operators The PRO 60C (AC202): 60 ft. power cable included with GTO SL-2200 dual (second) slide gate operator. GTO, Inc. gate operator accessories are warranted by the manufacturer against defects in materials and workmanship for a period of one year, unless otherwise stated, from the date of purchase provided recommended installation procedures have been followed.
  • Page 45: Installation Check List

    ___ Customer was instructed about proper use of transmitter and (or) other entry controls. ___ Customer was asked to fill out customer support card and mail it to GTO, Inc. ___ Customer was asked to retain all receipts (receipts provide proof of warranty).

This manual is also suitable for:

Pro sl-2000

Table of Contents