"Brewing time "
For energy saving purposes, the display will reduce
its luminosity after one hour of continuous inactivity
without dispensing anything. After two hours of con-
tinuous inactivity without dispensing anything, it will
switch itself off altogether.

9.4. Operating Safety Devices

When the coffee maker is switched ON, it checks
whether there is enough water in the boiler.
9.4.1. If the water level is inadequate, the machine
tops up the level automatically. If this does not
take place within a set period, the boiler filling
operation is discontinued and a warning message
is displayed:
"G01 Water missing"
9.4.2. If the water presence check result is positive,
the boiler heating resistances are enabled.
If the set pressure is not reached within a specific
time, the power supply to the heating resistances
is cut off and a warning message is shown on the
display:
"G02 Boiler Pressure low"
9.4.3. If the safety device for slow dispensing interve-
nes, the LED of the dispensing button must flash
until the end of dispensing.
The boiler safety devices can be reset by switching
the machine OFF and then back ON again

9.5 .The Cup-Warmer

By pressing the relative button, the display shows
the following:
Depending on the darkened segments it indicates the
selected power status of the cup-warmer resistances
(min – med – max – off).
passing from one level to the next is performed by
pressing on the cup-warmer key.

9.6. List of malfunctions

The system electronics are capable of diagnosing
the following failures by displaying the relative error
codes on screen:
Because they are serious, these errors will stop and
block machine operations.
G00
Check CPU
G01
Water missing
G02
Boiler Pressure low
G03
Boiler probe shorted
G04
Interrupted boiler probe
G05
Connection IDS
G06
Regen. softener
G0
Maintenance
G08
Cleaning interrupted
G0
24V Group 1 shorted
G10
24V Group 2 shorted
G11
24V Group 3 shorted
G12
24V Group 4 shorted
G13
24V Func. Group shorted
G14
12V Capacitive level shorted
G15
12V Transducer shorted
G16
2V Flowmeter shorted
G1
5V ext shorted
G18
12V sk power shorted
Failures G06--8- will not block the machine functions
and are displayed on the error codes log..
warning
9.7 List of
The system electronics are capable of diagnosing the
following failures by displaying the relative error code
on screen (which will come flashing on alternatively
to the customisation logos).
Because they are not serious, these errors will allow
the machine to keep running.
We nevertheless recommend that you contact the
Technical Service Department in order to settle the
problem as quickly as possible.
W01
Interr. flowmeter Group 1
W02
Interr. flowmeter Group 2
W03
Interr. flowmeter Group 3
W04
Interr. flowmeter Group 4
W05
iSteam probe shorted
W06
Interr. iSteam probe
W0
Check data
W08
Maintenance
W0
Water softener
W10
Run the coffee cleaning cycle
W11
Check the clock
W12
EV Group 1 shorted
W13
Interr. EV Group 1
W14
EV Group 2 shorted
W15
Interr. EV Group 2
W16
EV Group 3 shorted
W1
EV Group 4 shorted
W18
EV Autofill shorted
W19
Interr. EV Autofill
W20
EV Hot water shorted
W21
Interr. EV Hot water
W22
EV cold 4-TEA shorted
83