Iec 61162-1 Data Sentences - Furuno FCV-628 Operator's Manual

Table of Contents

Advertisement

4. INSTALLATION
Connect to XDR port
at rear of display unit
MJ-A10SPF
MJ-A6SRMD
Tape connectors with
vulcanizing tape and
then vinyl tape to
waterproof them.
Bind tape ends with
cable ties to prevent
tape from unraveling.
From
sensor
Connection of conversion cable 02S4147
Matching box for optional transducer
The optional matching box (Type: MB-1100,
Code No.: 000-041-353) is required to
connect the optional transducers 50B-6,
50B-6B, 200B-5S, and 50/200-1T.
Part
Type
Match-
MB-1100
ing Box*
Crimp-on
FV1.25-3
Lug
(LF)
Cord
NC-1
Lock**
*: With 10P connector cable
**: For connecting two transducers
Jumper block setting
Transducer
J2: No output reduction (default)
50B-6/6B
J1: Output reduction
50kHz
J2
J1
TB2
SHIELD
1
RED
2
RED
3
BLK
200kHz
4
BLK
5
Detach grommet;
Transducer
attach cord lock.
200B-5S
MJ-A10SRMD
From
transducer
Code no.
Qty
000-041-000
1
000-116-756-
6
10
000-168-230-
1
10
02P6348
Green
(shield)
TB1
WHT
3
2
1
BLK
Connect 10P
connector to
XDR port on
rear of
display unit.
Vinyl sheath
Taping
Shrink tubing
4.9
IEC 61162-1 Data
Sentences
The table below shows the data sentences
which can be input to and output from your
fish finder. The transmission speed for both
input and output is 4,800 bps. Data is output
at two-second intervals.
Input/output data sentences
Sentence
BWC
Bearing (magnetic) and dis-
tance to waypoint
GGA
Global positioning system
(GPS) fix data
GLL
Geographic position - latitude/
longitude
GNS
GNSS fix data
HDG
Heading, deviation and varia-
tion
HDT
Heading, true
MDA
Atmospheric pressure
MTW
Water temperature.
MWV
Wind speed and angle
RMA
Lat/Lon, SOG, course
RMB
Nav data (waypoint, etc.)
RMC
Lat/Lon (GPS), SOG, course
VHW
Water speed and heading
VTG
Course over ground and
ground speed
XTE
Cross track error
ZDA
Time and date
46
Crimp-on lug
FV1.25-3 (LF)
Shield
Meaning

Hide quick links: