The company strongly recommends the use of
certified fuel for its stoves (DINplus and Ö-Norm
M7135).
The use of fuel of inferior quality or not conforming
to the specification given above compromises the
running of your stove and can therefore lead to the
termination
manufacturer's responsibility for the product.
Pellet stoves only work with pellets having a
diameter of 6-8 mm with a length ranging from 5mm
to max 30 mm.

PRECAUTIONS FOR INSTALLATION

2.2.
IMPORTANT!
Installation and assembly of the stove must be
carried out by qualified personnel.
The stove must be installed in a suitable position to allow the normal
operations of opening and ordinary maintenance.
The site must be:
capable of providing the environmental conditions for operation
equipped with power supply 230V 50 Hz
capable of taking an adequate system for smoke discharge
provided with external ventilation
provided with an earth connection complying with CEI 64-8
The stove must be connected to a flue pipe or an internal or
external vertical duct conforming to current standards UNI
7129 - 7131 9615.
The stove must be positioned in such a way that the electrical
plug is accessible.
IMPORTANT!
The stove must be connected to a flue pipe or a
vertical duct which can discharge the fumes at the
highest point of the building.
The fumes are however derived from the combustion
of wood products, and if they come into contact with
or close to walls, they can make dirty marks.
Also take care because the fumes are very hot but
almost invisible, and can cause burns on contact.
The holes for the passage of the smoke pipe and for
the intake of air from outside should be made before
positioning the stove unit.
Theoretical notions for installation
INSTALLATION AND USE MANUAL
of
the
guarantee
PELLET STOVES
and
of
the
Technical service - Rights reserved - Reproduction prohibited