Scanner And Cable Terminations Scanner Pinout Connections - Metrologic MS7320 InVista Series Installation And User Manual

Fixed mount laser bar code scanner
Hide thumbs Also See for MS7320 InVista Series:
Table of Contents

Advertisement

S
CANNER AND
Scanner Pinout Connections
The MS7320 scanner interfaces terminate to 10-pin modular jacks located on the
back of the unit. The serial # label indicates the model number of the scanner.
MS732x-13 OCIA
Pin
Function
1
Ground
2
NC
3
NC
4
RDATA
5
RDATA Return
6
Clock in
7
Clock out
Clock in Return/
8
Clock out Rtrn
9
+5VDC
10
Shield Ground
44
C
T
ABLE
ERMINATIONS
Figure 31: Scanner Interface Ports
MS732x-13 IBM 46xx
Pin
Function
1
Ground
2
RS232 Transmit Output
3
RS232 Receive Input
4
RTS Output
5
CTS Input
6
DTR
7
IBM B- (D-)
8
IBM A+ (D+)
9
+5V IN
10
NC