Metrologic TECH 7 Installation And User Manual

Metrologic instruments laser bar code projection scanner installation and user's guide
Hide thumbs Also See for TECH 7:

Advertisement

Quick Links

METROLOGIC
INSTRUMENTS, INC.
®
TECH 7
Laser Bar Code
®
Projection Scanner
Installation and User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Metrologic TECH 7

  • Page 1 METROLOGIC INSTRUMENTS, INC. ® TECH 7 Laser Bar Code ® Projection Scanner Installation and User’s Guide...
  • Page 2 Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief pas- sages in a review, or provided for in the Copyright Act of 1976.
  • Page 3: Table Of Contents

    Parts of Scanner ........6...
  • Page 5: Introduction

    NEMA-12 steel case. The case construction enables the scanner to operate in harsh surroundings, especially industrial environments. Water-resistant, shock-resistant, and rugged, the TECH 7 is also fast, aggressive and reliable. It can register bar codes at a range of 76mm - 254mm (3"...
  • Page 6: Scanner Installation

    1. "Power off" the host system. 2. Locate the 19-pin female end of the scanner link cable and find the widest key located above pins L and A. Align this key with the corresponding key on the scanner box's Mil spec connector.
  • Page 7: Configuration To The Host System

    Guide by an asterisk that appears before the brief definition located next to the bar code. In order for the scanner to communicate with a host system properly, it may need to be programmed. Since each host system is unique, con- figure the scanner to match the host system requirements.
  • Page 8: Stand Installation

    Y in Figure 3. 4. Fasten the scanner to the stand by inserting the four 6-32 x ½ inch screws into the four holes in the scanner's case. Figure 1: Stand Orientation Horizontal Mount 3.00 in...
  • Page 9: Back Plate Installation

    Y in Figure 5. 3. Fasten the scanner to the back plate by inserting the four 6-32 x ½ inch screws into the four holes in the scanner's case. Fasten the scanner and back plate to the work surface.
  • Page 10: Parts Of Scanner

    The communication cable may include a power supply or it may be designed to draw power directly from the host device. The standard TECH 7 has one connector. (When the atrium option is installed, a second connector is installed on the unit to connect the MX001 Industrial Control Interface box.)
  • Page 11: Visual Indicators

    Visual Indicators There is a red and green LED at the top of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the scan and scanner. Steady Green When the laser is on, the green LED is also on. This occurs when an object is in the scan field.
  • Page 12 La diode verte reste allumée; la diode rouge clignote Après lecture avec succès d'un code à barres par le scanner, la diode rouge se met à clignoter, suivie d'un bip sonore unique. Si la diode rouge ne clignote pas ou quand aucun bip sonore n'est émis, cela sig-...
  • Page 13 Optische Anzeigen Auf dem Scanner befinden sich eine rote und eine grüne Leuchtdiode. Bei eingeschaltetem Scanner geben Ihnen die blinkenden bzw. feststehenden Leuchtdiodenanzeigen Aufschluß über den Abtast-und Scannerstatus. Weder rote noch grüne Leuchtdiodenanzeige Es gibt zwei mögliche Gründe, weshalb die Leuchtdiodenanzeigen nicht aufleuchten.
  • Page 14 Il diodo luminoso verde è acceso; quello rosso lampeggia Dopo la lettura riuscita di un codice a barre da parte dello scanner il diodo luminoso rosso lampeggia e quindi viene emesso un unico seg- nale beep.
  • Page 15: Labels

    There is one label located inside the window of the scanner noting that this device is a CDRH Class IIa laser product and IEC 825 LASERKLASSE 1. Also, on the scanner is a label located on the back of the unit. This label contains information such as the model number, date of manufacture, serial number, and approvals.
  • Page 16: Depth Of Scan Field For The Ms770 Scanner

    Depth of Scan Field for the MS770 Scanner The depth of field for the scanner is 76mm to 254mm (3.00” - 10.00”) from the laser output window. Pass the symbol through the scan area in order for the scanner to recognize the bar code. (Refer to Figure 7) 76 mm [3.00 in]...
  • Page 17: Depth Of Scan Field For The Ms775 Scanner

    Depth of Scan Field for the MS775 Scanner The depth of field for the scanner is 76mm to 254mm (3.00” - 10.00”) from the laser output window. Pass the symbol through the scan area in order for the scanner to recognize the bar code. (Refer to Figure 8) 76 mm [3.00 in]...
  • Page 18: Maintenance

    Therefore, the output window will need occasional cleaning. 1. Spray glass cleaner onto lint free, nonabrasive cleaning cloth. 2. Gently wipe the output window. Applications and Protocols The model number on each scanner includes the scanner number and communications protocol. Version Identifier Communication Protocol(s)
  • Page 19: Appendix A Specifications

    Operating Current: Standby Current: DC Transformers: Specifications subject to change without notice Industrial Projection Scanner Visible Laser Diode 650 ± 5 nm or 670 ± 5 nm CLASS IIa laser product CE, UL listed for the US and CUL for...
  • Page 20: Operational

    Appendix A (Continued) Operational Depth of Scan Field: Scan Speed: Scan Pattern: Indicators: Beeper Operation: Maintenance Required: Decode Capability: System Interfaces: Optional: Print Contrast: Roll, Pitch, Yaw: Environmental Storage Temperature: Operating Temperature: Humidity: Light Levels: Ventilation: Shock: ESD: Contaminants: Specifications subject to change without notice. 76mm to 254 mm (3 in to 10 in) Model 770: 2000 scan lines per second Model 775: 1200 scan lines per second...
  • Page 21: Pin Assignments

    Version "1" Pin Assignments for RS-232, OCIA, and Bi-direc- tional RS-232 Each TECH 7 scanner has a 19-pin male Mil spec connector that is located on the side of the unit. To connect the scanner to the host device, use a communication cable with a female Mil spec connector.
  • Page 22 Appendix B (Continued) Version "15" Pin Assignments for Light Pen Emulation Each TECH 7 scanner has a 19-pin male Mil spec connector that is located on the side of the unit. To connect the scanner to the host device, use a communication cable with a female Mil spec connector.
  • Page 23: Warranty And Disclaimer

    The Tech 7 scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The Tech 7 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all Tech 7 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.
  • Page 24: Notices

    Never attempt to look at the laser beam, even if the scanner appears to be nonfunc- tional. Never open the scanner in an attempt to look into the device. Doing so could result in haz- ardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard.
  • Page 25 Appendix D (Continued) European Standard Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Funkstöreigenschaften nach EN 55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen;...
  • Page 26: Patents

    Appendix E Patents “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No. 4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,607,156; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,923,281; 4,933,538; 4,960,985; 4,992,717; 5,015,833; 5,017,765; 5,059,779; 5,081,342; 5,117,098; 5,124,539;...
  • Page 27: Index

    Autodiscriminate 1, 16 Back Plate 1, 5, 15 Bidirectional RS-232 14, 17 Cable 2, 6, 17, 18 communication 1, 6 scanner link 2 Caution 2, 21 Compliance 2, 11, 15 Configure 3 Connector 2, 6 mil spec 2, 6, 17, 18...
  • Page 28 Index Scan pattern 1, 16 Scan Speed 16 ScanSelect 3 ScanSet® 3 Service Center 7 Specifications 15 Stand 1, 4, 15 Visual Indicators 7, 8, 9, 16 Voltage 15 Warning 21 Warranty 19 Window 6, 11, 14...
  • Page 32 March 2006 Printed in the USA...