9.

INSTALLATION INSTRUCTIONS

CARTON CONTENT
1
Quantec Combi Appliance
2
Group Set Components Pack
Gas Valve Pack
Filling Loop pack
Return Valve Pack
Flow Valve Pack
DHW Pack
Accessory Pack
Copper connection pack
3
Wall Mounting Plate
4

Wall Mounting Template

5
Installation & Users Instructions
COPPER CONNECTIONS PACK
9.1
WALL MOUNTING TEMPLATE
Use a plumb line to make sure the unit is square. Fix the template to the wall. Mark the positions of the flue
and 4 fixing points.
9.1.1
Using a 105 mm core drill make the hole through the wall. Installations that are made from within the
building only will require a 125 mm diameter hole in order to fit the flue system.
9.1.2
Using a 7mm bit, drill a minimum of 4 fixing holes for the wall plate. Insert the Rawlplugs. Remove
the template.
9.2

FIXING THE APPLIANCE

This
Caution:
recommended weight for a one-man lift as
detailed in the Manual Handling Operations,1992
Regulations.
9.2.1
It should be noted this appliance could
contain sharp edges and care MUST be
taken when handling.
9.2.2
Screw the wall bracket to the wall using
the 4 screws provided.
9.2.3
Lift the appliance onto the fixing bracket
and lower into position.
Sales/Spares & Replacement Help Line 01604 762881
GAS VALVE PACK
1
1
1
RETURN VALVE PACK
1
1
1
1
1
FLOW VALVE PACK
1
1
1
1
DHW PACK
FIGURE 7. CARTON CONTENTS