ASSEMBLING THE VENTILATION
SHAFT

Outdoor evacuation

— Using the two screws (fig. 1), attach the metal
chimney bracket against the wall, flush with the
ceiling for support.
— Mount the back-flow valve near the motor out-
let (fig. 2). This back-flow valve makes it possible
to block the entry of air from the outside.
— If a 125 mm flue is being installed, use the
adapter provided (fig. 3).
If the diameter of your exterior flue is less than
125 mm, you must connect your hood in recy-
cling mode.
— Slide the end of the flue over the motor outlet
(fig. 4).
— Prepare your telescoping ventilation shaft, tak-
ing care not to block the vents (fig. 4).
Fit the ventilation shafts into one another as far
as they will go.
— Attach the upper portion of the chimney (B/fig.
4 on the metal chimney bracket (A/fig. 4) using
the two screws (G/fig. 4).
— Adjust the length of the telescoping chimney
by bringing down the lower part and fitting it into
the top of the hood.
A
Chimney bracket
Telescoping ventilation shaft
B
C
Flue
D
Adapter
E
Back-flow valve
F
Motor outlet
G
Chimney holding screw
fig. 2
A
C
D
E
F
54
fig. 1
fig. 3
G
B
fig. 4