Specifications
Function
Range
DC Voltage
400mV
4V
40V
400V
600V
AC Voltage
50 to 60Hz
400mV
4V
40V
400V
600V
DC Current
400A
4000A
40mA
400mA
4A
20A
AC Current
50 to 60Hz
40mA
400mA
20A
Resistance
400
4k
40k
400k
4M
40M
Capacitance
4nF
40nF
400nF
4F
40F
400F
4mF
40mF
Temp
-30 to 1000C 1C
(type-K)
-22 to 1832F 1F
Pulse Width
1.0 to 20.0ms 0.1ms
Diode
1.0mA test; 1mV resolution
Continuity
Audible threshold: 35
Resolution
0.1mV
(0.5% reading + 3 digits)
0.001V
(1.5% reading + 2 digits)
0.01V
0.1V
1V
(1.8% reading + 2 digits)
(1.5% reading + 5 digits)
0.1mV
0.001V
(1.0% reading + 3 digits)
0.01V
(1.5% reading + 3 digits)
0.1V
1V
(2.0% reading + 4 digits)
0.1A
1A
(1.5% reading + 3 digits)
0.01mA
0.1mA
0.001A
(2.5% reading + 5 digits)
0.01A
0.01mA
(1.8% reading + 5 digits)
0.1mA
0.01A
(3.0% reading + 7 digits)
(1.2% reading + 4 digits)
0.1
(1.0% reading + 2 digits)
0.001k
0.01k
(1.2% reading + 2 digits)
0.1k
0.001M
(2.0% reading + 3 digits)
0.01M
(5.0% reading + 50 digits)
1pF
10pF
(5.0% reading + 7 digits)
0.1nF
1nF
(3.0% reading + 5 digits)
10nF
0.1F
(10.0% reading + 10 digits)
0.001mF
0.01mF
(3.0% reading + 5C or 8F)
(probe accuracy not included)
(2.0% reading + 20 digits)
(5.0% reading + 15 digits)
Test Current: <1mA DC typical
14
Accuracy
AUT500-EU-EN v1.0 5/13
Need help?
Do you have a question about the AUT500 and is the answer not in the manual?
Questions and answers