Starting Electric Start Engines - Generac Power Systems 005626-0 Owner's Manual

Gp series 7,000 & 8,000 watt portable generator
Hide thumbs Also See for 005626-0:
Table of Contents

Advertisement

Available languages

Available languages

Figure 11 - Fuel Shut-off Valve
If engine fires, but does not continue to run, move choke lever to
FULL CHOKE and repeat starting instructions.
Figure 12 - Choke Position
Choke
IMPORTANT: Do not overload the generator. Also, do not overload
individual panel receptacles. These outlets are protected against
overload with push-to-reset-type circuit breakers. If amperage rating
of any circuit breaker is exceeded, that breaker opens and electrical
output to that receptacle is lost. Read "Don't Overload the Generator"
carefully.

2.9 STARTING ELECTRIC START ENGINES

Never start or stop engine with electrical
devices plugged into the receptacles AND
devices turned on.
Unplug all electrical loads from the unit's receptacles before
starting the engine.
Make sure the unit is in a level position.
Open the fuel shut-off valve (Figures 11 and 13).
Move engine CHOKE knob outward to
(Figure 14).
NOTE:
"Full Choke" position
Section 2 – Operation
Portable Generator System
Figure 13 - Fuel Shut-off Valve
To start engine, press and hold the Start/Run/Stop switch in the
"Start" position. The engine will crank and attempt to start. When
the engine starts, release the switch to the run position.
When the engine starts, move choke knob to "1/2 Choke" position
until the engine runs smoothly and then fully in to the "Run" position.
If engine falters, move choke knob back out to "1/2 Choke" position
until the engine runs smoothly and then to "Run" position.
This generator is also equipped with a manual recoil starter which
may be used if the battery is discharged.
The switch must be in the RUN position.
To start manually, firmly grasp the recoil handle and pull slowly
until increased resistance is felt. Pull rapidly up and away to start
engine. Then follow the same choke sequence.
Figure 14 - Choke Position
Choke
Start/Run/Stop Switch
If engine fires, but does not continue to run, move choke lever to
"Full Choke" and repeat starting instructions.
IMPORTANT: Do not overload the generator. Also, do not overload
individual panel receptacles. These outlets are protected against
overload with push-to-reset-type circuit breakers. If amperage rating
of any circuit breaker is exceeded, that breaker opens and electrical
output to that receptacle is lost. Read "Don't Overload the Generator"
carefully.
NOTE:
NOTE:
9