Alliance Laundry Systems CHD25G2-CA025L Installation Operation & Maintenance

Alliance Laundry Systems CHD25G2-CA025L Installation Operation & Maintenance

25 pound (11.3 kilogram) capacity 30 pound (13.6 kilogram) capacity 35 pound (16 kilogram) capacity stacked 30 pound (13.6 kilogram) capacity stacked 45 pound (20.4 kilogram) capacity 55 pound (25 kilogram) capacity starting serial no. 0602004144
Hide thumbs Also See for CHD25G2-CA025L:
Table of Contents

Advertisement

Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
25 Pound (11.3 Kilogram) Capacity
30 Pound (13.6 Kilogram) Capacity
35 Pound (16 Kilogram) Capacity
Stacked 30 Pound (13.6 Kilogram) Capacity
Stacked 45 Pound (20.4 Kilogram) Capacity
55 Pound (25 Kilogram) Capacity
Starting Serial No. 0602004144
Refer to Page 6 for Model Identification
Tumble Dryers
www.alliancelaundry.com
Part No. 70458301ENR7
January 2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHD25G2-CA025L and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alliance Laundry Systems CHD25G2-CA025L

  • Page 1 Tumble Dryers 25 Pound (11.3 Kilogram) Capacity 30 Pound (13.6 Kilogram) Capacity 35 Pound (16 Kilogram) Capacity Stacked 30 Pound (13.6 Kilogram) Capacity Stacked 45 Pound (20.4 Kilogram) Capacity 55 Pound (25 Kilogram) Capacity Starting Serial No. 0602004144 Refer to Page 6 for Model Identification Original Instructions Keep These Instructions for Future Reference.
  • Page 3: Front Matter

    Never start the tumble dryer with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumble dryer is properly grounded. W002R1 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 4 A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance. • This appliance must not be installed in a bedroom or bathroom. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 5: Table Of Contents

    All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 6 Models Starting Serial No. 0909xxxxx............ 100 Resetting Cycle Time to Zero..............100 Dipswitch Settings..................101 Topoffs..................... 105 Temperature Selector Switch..............105 To Program a Short Test Cycle..............105 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 7 Door Strike....................129 Maintenance..................131 Daily......................131 Monthly....................131 Quarterly....................132 Bi-Annually....................132 Annually....................132 Fire Suppression System Maintenance Test..........132 Before You Call for Service...............134 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 8 Removing Tumble Dryer from Service..........135 Disposal of Unit.................136 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 9: Introduction

    IPD25E2 BA025N SA025L YU025L DR25G2- BK025N SA025N YU025N DR25G2- SK025N BK025R SK025R DR25G2- ST025L BT025L DR25G2- BT025N DR25G2- BT025R DR25G2- BU025L DR25G2- BU025N DR25G2- BU025R © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 10 DR30G2- BK030N SA030L YU030L DR30G2- SA030N YU030N BK030R SK030N DR30G2- SK030R BT030D ST030D DR30G2- BT030L DR30G2- BT030N DR30G2- BT030R DR30G2- BU030L DR30G2- BU030N DR30G2- BU030R © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 11 UTT30R DR335G2- MTT30N UUT30L BUT30R MTT30R UUT30N DRST30G2- NTT30N UUT30R BAT30L SAT30L DRST30G2- BAT30N SAT30N DRST30G2- BTT30D DRST30G2- BTT30L DRST30G2- BTT30N DRST30G2- BUT30L DRST30G2- BUT30N © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 12 DR35G2- SA035N BA035N SK035N DR35G2- BK035N SK035R DR35G2- ST035L BK035R ST035N DR35G2- ST035R BT035L SU035L DR35G2- BT035N DR35G2- BT035R DR35G2- BU035L DR35G2- BU035N DR35G2- BU035R © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 13 MTT45N DR445G2- MTT45R BUT45R NTT45N DRST45G2- BAT45L SAT45L DRST45G2- SAT45N BAT45N SKT45N DRST45G2- SKT45R BTT45D STT45D DRST45G2- BTT45L STT45L DRST45G2- BTT45N DRST45G2- BUT45L DRST45G2- BUT45N © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 14 Explanation of digit in 6th position of model number: D = Liquid Petroleum (L.P.) Gas, Japan E = Electric F = Reduced Electric (Eco Line) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 15 ZY – NetMaster network, prep for card EO – LED OPL QT – dual digital timer KB – reversing single coin KC – single coin © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 16: Contact Information

    Figure 1 . or +32 56 41 20 54 for the name and address of the nearest Date Purchased ______________________________ authorized parts distributor. Serial Plate Figure 1 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 17: Safety Information

    Daily remove piled up dust from filter and inside of filter compartment. W051R1 • Do not use or store flammable materials near this appliance. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 18 Always clean the lint filter daily. Keep area around the exhaust opening and adjacent surrounding area free from the accumulation of lint, dust and dirt. The interior of the tumble © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 19: Specifications And Dimensions

    1/4 (0.1865) 1/4 (0.1865) 1/4 (0.1865) Nonreversing 1/2 (0.373) Horsepower (kW) Reversing 1/4 (0.1865) Fan Motor: 1/4 (0.1865) 1/4 (0.1865) 1/4 (0.1865) 1/2 (0.373) Horsepower (kW) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 20 Eco Line - 12 kW Eco Line - 18 kW Rating: Eco Line - 12 kW Standard Classic Line - 12 kW Eco Line - 9 kW Steam Models © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 21 33 x 30 (838 x 762) Inch (mm) Cylinder Capacity (dry weight): 2 x 30 (2 x 13.6) 2 x 45 (2 x 20.5) kg (Pounds) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 22 (27.8, 100.2) (23.5, 84.4) Electric Models Heating Element Rating**: Classic Line - 21 kW Eco Line - 12 kW Steam Models Steam Connection 3/4 in. NPT © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 23: Cabinet Dimensions - 025, 030, 035 And 055 Series

    030 Series 26.25 in. 27.5 in. 28.35 in. 31.75 in. 46.875 in. 6.53 in. (667 mm) (669 mm) (720 mm) (806 mm) (1,191 mm) (166 mm) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 24 * Fire suppression system optional - may not be on machine. NOTE: Facia panels available to increase height of models to 72.25 inches (1,835 mm) and 76.25 inches (1,938 mm). © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 25: Cabinet Dimensions - T30 And T45 Series

    81.25 in. (746 mm) (1,235 mm) (775 mm) (2,063.75 mm) NOTE: To meet ADA compliance, install a 4 inch (102 mm) riser on T30 models only. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 26: Exhaust Outlet Locations - 025, 030, 035 And 055 Series

    4.625 in. (117 mm) 035 Series Classic Line Eco Line 4.875 in. (124 mm) 5.625 in. (143 mm) 8 in. (203 mm) 6 in. (152 mm) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 27 Specifications and Dimensions Rear Exhaust Models Diameter 055 Series 8 in. (203 mm) 4.808 in. (122 mm) 6.156 in. (156.3 mm) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 28: Exhaust Outlet Locations - T30 And T45 Series

    Round Fits 6 in. (203 mm) (152 mm) T45 Series Elliptical Fits 10 in. (254 mm) 40.88 in. 4.75 in. (121 mm) 66.00 in. (1,038 mm) (1,676 mm) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 29: Gas Connection Locations - 025, 030, 035 And 055 Series

    59 in. (1,500 mm) 1.5 in. (38.1 mm) 35 in. (889 mm) 35 Series 59 in. (1,500 mm) 2.5 in. (64 mm) 35 in. (889 mm) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 30 57 in. (1,450 mm) 4 in. (101.6 mm) 43 in. (1,092 mm) 55 Series 55.285 in. (1,404 mm) 1.621 in. (41.17 mm) 46.75 in. (1,187.45 mm) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 31: Gas Connection Locations - T30 And T45 Series

    75.20 in. (1,910 mm) 1.74 in. (44 mm) 36.84 in. (936 mm) Australian CE and Australian 75.28 in. (1,912 mm) 2.5 in. (64 mm) 30.60 in. (777 mm) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 32 Specifications and Dimensions Gas Connection Models T45 Series 78.75 in. (2,000 mm) 4.12 in. (105 mm) 42.88 in. (1,089 mm) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 33: Electrical Connection Locations - 025, 030, 035 And 055 Series

    28 in. (711 mm) 3.25 in. (83 mm) 035 Series 62.25 in. (1,581 mm) 3 in. (76 mm) 28 in. (711 mm) 4.25 in. (108 mm) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 34: Electrical Connection Locations - T30 And T45 Series

    Gas and Steam Models Electric Models T30 Series 59 in. (1,498 mm) 1.75 in. (44 mm) 35.63 in. 73.21 in. 2.28 in. (58 mm) (905 mm) (1,859 mm) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 35 Specifications and Dimensions Electric Service Models Gas and Steam Models Electric Models T45 Series 62.5 in. 1.75 in. (44 mm) (1,588 mm) N/A = Not Applicable © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 36: Steam Connection Locations - 025, 030 And 035 Series

    025/030/035 Series 53.75 in. (1,365 mm) 6.29 in. (160 mm) 42.5 in. (1,080 mm) 2.39 in. (61 mm) NOTE: All connections use 3/4 in. NPT pipe. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 37: Steam Connection Locations - T30 Series

    T30 Series (Lower) 36.35 in. (923 mm) 6.29 in. (160 mm) 25.13 in. (638 mm) 2.39 in. (61 mm) NOTE: All connections use 3/4 in. NPT pipe. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 38: Installation

    To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances, and/or local codes and ordinances. W770 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 39: Position And Level The Tumble Dryer

    0.125 inch (3.18 mm) higher in the front. Refer to Figure 3 . Tumble dryer must not rock. Lock leveling legs with nuts previously installed. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 40: Fifth Leveling Leg

    40°F and 120°F (4.4°C and 48.9°C) . If water in the supply line or water solenoid valve freezes, the fire suppression system will not operate. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 41: Water Connections

    (from literature pack) in water inlet hose NOTE: Replacement outlet hoses are available (at couplings. Refer to Figure 6 . extra cost). Order 44073304 Hose, 14 in. (36 cm ). © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 42: Electrical Requirements

    Refer to Figure 8 . Remove lint panel. IMPORTANT: Support door and hinge assembly securely to prevent it from dropping once side screws are removed from door hinge lug. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 43 Reinstall switch, orienting button toward center of machine. Reinstall plug in switch’s previous location. Refer to Figure 9 . © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 44: Before Placing Tumble Dryer Into Service

    13. Adjust door catch if necessary to allow 7 – 15 pounds (0.48 – 1.03 bar) pull at center of handle. 14. Reinstall control assembly using mounting screws. 15. Reinstall control panel and lint panel. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 45 It may be necessary to retry several times to bleed air from the gas lines. To reset, open and close the loading door and restart tumble dryer. Figure 13 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 46: Required For Ce Models Only

    Leave all literature and a signed Declaration of Conformity Once machine is installed, please be sure to complete the with customer. following items: • Review machine warranty information with customer. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 47: Installing Ce Gas Drying Tumble Dryer

    (mm) Part No. Quantity Natural Second 8/10 3.25 0.1540 M401020 2H(E) (20/25, 2.0/2.5) (8, 0.8) (3.9) 0.1570 M402996 (4.0) 0.1570 M402996 (4.0) 0.1820 M411371 (4.6) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 48 0.1820 M411371 (4.6) 0.2040 M402993 (5.2) 8 (20, 2.0) 0.1220 70070903 regulated (3.1) 0.1299 44253801 (3.3) 0.1299 44253801 (3.3) 0.1440 M400998 (3.7) 0.1440 M400998 (3.7) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 49 M401017 (3.0) 14.9/20 0.0820 M401027 (37/50, 3.7/5.0) (30, 3.0) (2.1) 0.0866 70070906 (2.2) 0.0866 70070906 (2.2) 0.0980 M406361 (2.5) 0.0935 M403017 (2.4) 0.1200 M401017 (3.0) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 50: Properties Of Ce Gases

    (MJ/m (MJ/m (MJ/m (MJ/m Density Natural Second 1226 1362 1014 0.555 2H,E Applicable (45.67) (34.02) (50.72) (37.78) 1004 1115 0.612 Applicable (37.38) (29.25) (41.52) (32.49) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 51: Changing Gas Configuration

    (located ahead of the tumble dryer) that will maintain the gas supply at the inlet pressure specified. W430R1 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 52: Specific Conversion Procedures

    Models Starting 1/1/14 . Install the new, correct burner orifice(s). Refer to Figure 17 Burner Orifice and Table 1 . Torque each to 9 – 10 Nm. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 53 Required Burner Manifold Pressure Manometer Connect Over Loosened Slotted Pressure Tap Screw in Bottom of Gas Valve 10 Spud Holder Figure 15 Models Through 12/31/13 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 54 Replace regulator cap. Refer to Figure 15 Models Through 12/31/13 and Figure 16 Models Starting 1/1/14 . Commission tumble dryer for use. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 55: Exhaust Requirements

    Proper sized exhaust ducts are essential for proper operation. All elbows should be sweep type. Exhaust ducts must be assembled © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 56 Consult your local building code for regulations which may also NOTE: Where exhaust duct pierces a combustible wall apply. or ceiling, the opening must be sized per local codes. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 57: Individual Venting

    Equivalent Length (meter) = 1.17 x Duct Diameter (mm) Table 3 Example: A 12 inch (305 mm) diameter duct’s equivalent length of 14 feet (4.3 m) of duct and two 90° elbows is: © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 58 16 in. (406 mm) 19 in. (483 mm) 24 in. (610 mm) 12 in. (305 mm) 18 in. (457 mm) 21 in. (533 mm) 26 in. (660 mm) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 59 NOTE: Table 4 represents units with the same vent NOTE: Duct clean-out recommended every 6 feet size. If multiple vent sizes are used, consult a local (183 cm) . HVAC specialist. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 60 Outlet duct diameter = combined largest duct diameter of both sides 45° typical Figure 21 Two Manifold Assemblies Refer to Table 4 for measurements for each manifold. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 61: Gas Requirements

    Installation Code in Canada 025 Series M6699P3 • In Australia and New Zealand , installation must comply with the Gas Installations Standard AS/NZS 5601 Part 1: General Installations. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 62 To reduce the risk of explosion or fire, DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS! Gas connections should be checked twice a year for leakage. W635 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 63: Gas Supply Pipe Sizing And Looping

    Stacked 45 series tumble dryers = 95,000 Btu/hr. (100.23 Mj/hr., 27.8 kW) per pocket; 190,000 total Btu/hr. (200.45 Mj/hr., 55.6 kW) for machine; 055 series tumble dryers = 112,000 Btu/hr. (118.16 Mj/hr., 32.8 kW) each Figure 23 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 64 2 (50.80) 2 (50.80) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 1,200,000 2 (50.80) 2 (50.80) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 65: High Altitude Burner Orifice Sizing

    For L.P. Gas, correct the total Btu/hr by multiplying it by 0.6. The answer is the equivalent Btu on the above chart. Table 5 High Altitude Burner Orifice Sizing © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 66 0.1470 (3.7) M401000 55,480 ( 1,831-2,440) (58.53) 8,001-10,000 0.1405 (3.6) M401014 49,640 ( 2,441-3,050) (52.37) L.P. Gas 2,001-6,000 0.0935 (2.4) M403017 67,160 ( 610-1,830) (70.85) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 67 (87.35) 4,001-6,000 0.1695 (4.3) M402988 75,600 ( 1,221-1,830) (79.76) 6,001-8,000 0.1610 (4.1) M401002 68,400 ( 1,831-2,440) (72.16) 8,001-10,000 0.1570 (4.0) M402996 61,200 ( 2,441-3,050) (64.57) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 68 0.1015 (2.6) M411376 155,000 ( 1,831-2,440) (163.53) 8,001-10,000 0.0980 (2.5) M406361 142,600 ( 2,441-3,050) (150.44) Natural 2,001-4,000 0.1929 (4.9) M402994 104,360 ( 610-1,220) (110.1) Series © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 69 2,001-4,000 0.1200 (3.0) M401017 43,200 (46) Gas 50 (610-1,220) 4,001-6,000 0.1130 (2.9) M401022 37,800 (40) ( 1,221-1,830) 6,001-8,000 0.1110 (2.8) M411512 34,200 (36) ( 1,831-2,440) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 70 ( 610-1,220) 4,001-6,000 0.1250 (3.2) M402489 46,200 (49) ( 1,221-1,830) 6,001-8,000 0.1220 (3.1) 70070903 41,800 (44) ( 1,831-2,440) 8,001-10,000 0.1200 (3.0) M401017 37,400 (39) (2,441-3,050) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 71 0.1285 (---) M401021 41,800 (44) ( 1,831-2,440) 8,001-10,000 0.1220 (3.1) 70070903 37,400 (39) ( 2,441-3,050) Natural 2,001-4,000 0.1405 (3.6) M401014 58,880 (62) Gas 60 ( 610-1,220) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 72 M401014 54,400 (57) ( 2,441-3,050) Natural 2,001-4,000 0.1695 (4.3) M402988 82,800 (87) Gas 50 ( 610-1,220) Series 4,001-6,000 0.1610 (4.1) M401002 75,600 (80) ( 1,221-1,830) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 73 *Btu/hr. derate of 4% per 1,000 feet (305 meters) of altitude. NOTE: Eco line is only available in natural gas. Table 7 Eco Line Models © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 74: Electrical Requirements

    If more than one tumble dryer is being installed, a circuit breaker must be provided for each. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 75: Grounding Instructions

    CSA C22.1 latest edition Canadian Electrical Code, or local codes. Electrical work should be done tumble dryer ground screw does not constitute a ground. by a qualified electrician. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 76: For Ce Models Only

    Service/Ground Location Models Through 7/9/12 Heat Source Ground and Terminal Block Locations Non-CE Gas or Steam Control Tray Ground Screw Terminal Block © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 77 NOTE: Do not make service connections in control tray. Series Ground Lug Power Distribution Block Gas or Steam Models Through 7/31/11 Ground Screw Terminal Block © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 78 Table 9 Models Starting 7/10/12 Ground and Terminal Block Locations Non-CE Control Tray Power Distribution Block Ground Control Tray Power Distribution Block Ground Table 10 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 79 Power Distribution Block Ground Non-CE Electric Ground Power Distribution Block T30: Gas or Steam T45: Gas T30/T45 Terminal Block Power Disconnect (Models Through 7/31/11) Ground Screw © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 80: To Connect Electrical Service To The Tumble Dryer

    Refer to Table Table 11 11 for these models: NOTE: Electric models are not field convertible and must be connected to service specified on serial plate. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 81: Electrical Connections For T30 And T45 Only

    Complete ferrite installation instructions for all gas and steam models with OM control suffix. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 82: Conversion Instructions

    Volt jumper located in the literature packet in cylinder. Sign and date conversion sticker located on back of tumble dryer. Follow the instructions covered in Connecting Electrical Service section. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 83: Ferrite Ring Installation (025, 030, 035 And 055 Series Only)

    26 . Do not install the ferrite outside of the box or other service leads including ground. area. Make sure that service leads are in the center of the © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 84: Electrical Specifications

    208-240V/60Hz/1ph L1, L2, Neutral, 10A – 2 pole 14 (2.5) and ground 120V/60Hz/1ph L1, Neutral, and 7.5** 10A – 1 pole 14 (2.5) ground © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 85 440V/60Hz/3ph L1, L2, L3, and 10A* – 3 pole 14 (2.5) ground 460-480V/60Hz/3ph L1, L2, L3, and 10A* – 3 pole 14 (2.5) ground © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 86 380V/50Hz/3ph L1, L2, L3, and 10A* – 3 pole 14 (2.5) ground 400-415V/50Hz/3ph L1, L2, L3, and 10A* – 3 pole 14 (2.5) ground © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 87 L1, L2, L3, and ground 10A* – 3 pole 14 (2.5) 380V/50 or 60Hz/3ph L1, L2, L3, and ground 10A* – 3 pole 14 (2.5) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 88 9 kW Classic Line 025 Series Electric Models Serial Plate Terminal Block Serial Plate Amps Recommended Circuit Voltage Connections Required Nonreversing Reversing Breaker Rating Wire Size AWG © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 89 4 (25) and ground 200V/50Hz/1ph L1, Neutral, and 80A – 1 pole 4 (25) ground 200V/60Hz/1ph L1, L2 and ground 80A – 2 pole 4 (25) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 90 Wire Size AWG 208V/60Hz/1ph L1, L2, Neutral, 150A – 2 pole 1/0 (50) and ground 240V/60Hz/1ph L1, L2, Neutral, 125A – 2 pole 1 (35) and ground © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 91 N/A = Not Applicable Table 19 12 kW Eco Line 030 Series Electric Models Serial Plate Voltage Terminal Block Serial Plate Amps Recommended Circuit Connections Required © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 92 * These serial plate voltages are only options available on the T30 electric models. Current (Amp) is for one pocket only. ** Per heater on T30 electric models, each has two heaters. Table 21 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 93 200-208V/60Hz/3ph L1, L2, L3, and 90A* – 3 pole 3 (26.7) ground 200V/50Hz/3ph L1, L2, L3, and 90A* – 3 pole 3 (26.7) ground © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 94 * 3 Phase machines should not have fuses, breakers only. Table 24 27 kW Classic Line 055 Series Electric Models Serial Plate Terminal Block Serial Plate Amps Recommended Circuit Voltage Connections Required © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 95 Serial Plate Amps Recommended Circuit Voltage Connections Required Nonreversing Reversing Breaker Rating Wire Size AWG 380V/50Hz/3ph L1, L2, L3, and 40A* – 3 pole 6 (16) ground © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 96 Electrical Requirements 400-415V/50Hz/3ph L1, L2, L3, and 35A* – 3 pole 6 (16) ground * 3 Phase machines should not have fuses, breakers only. Table 26 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 97: Steam Requirements

    • In both steam supply and steam return line, it is recommended that each have a pipe union and shut-off valve. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 98 Trap with Built-In Strainer Vacuum Breaker (Optional) 18 in. (457 mm) Drop Solenoid Valve (Supplied with machine) 10 Union 11 Return 12 Supply Figure 27 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 99: Piping Recommendations

    Refer to Figure 27 for typical installations. Use flexible lines between steam inlet solenoid and steam coils, as well as outlet between steam coil and traps. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 100: Single Drop Timer

    To change the dry time on the tumble dryer, combinations of ON position. Restore power to the tumble dryer for 10 seconds dipswitches can be set on the control. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 101: Dipswitch Settings

    Set dipswitch 8 to OFF position and restore power to the tumble dryer. Dipswitch Settings Heat Switch Number Heat Time Per Coin Pulse (in minutes) 8 (factory default) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 102 Single Drop Timer Heat Switch Number Heat Time Per Coin Pulse (in minutes) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 103 Single Drop Timer Heat Switch Number Heat Time Per Coin Pulse (in minutes) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 104 Cool Down Per Cycle (in minutes) 1 (factory default) Table 28 Models Through Serial No. 0908xxxxx Cool Down Switch Number Cool Down Per Cycle (in minutes) Cycle Reset Switch Number © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 105: Topoffs

    High/Normal 4 flashes Medium/PP 3 flashes Low/Delicate 2 flashes Figure 28 No Heat 1 flash NOTE: To change dipswitch settings refer to Dipswitch Settings section. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 106: Error Codes

    Error Codes Display Definition Corrective Action AF (flashing) Airflow switch opened/closed 5 or more Check airflow switch. Replace if times in a running cycle. inoperative. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 107: Operating Instructions

    IMPORTANT: This appliance shall not be used to dry off solvents or dry cleaning fluids. Clean Lint Screen/Compartment Remove any accumulated lint from the lint screen and compartment. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 108: Reversing Operation

    The type of fabric being dried will determine the temperature setting. Consult the fabric care label or fabric manufacturer to determine proper temperature Figure 30 setting. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 109 Display will show minutes remaining before end of cycle. heat for 30 seconds every 2 minutes for 1 hour OR until the loading door is opened. Figure 34 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 110: Electronic Opl Micro Control

    Manual. HIGH temperature** 190°F (88°C) MED temperature* 160°F ( 71°C) MED temperature** 165°F ( 74°C) MED LOW temperature* 145°F (63°C) MED LOW 155°F (68°C) temperature** © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 111: Single Drop Control

    To stop the tumble dryer at any time, open the door or press STOP/RESET. Figure 40 Insert the coin(s) in the coin slot. Figure 39 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 112: Mdc Coin And Card Control

    Select temperature by pressing the appropriate temperature To prevent the risk of fire, remove laundry pad. immediately in case of power failure. HIGH Temperature 190°F W779 (88°C) Temperature 180°F (82°C) © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 113: Quantum Control

    Temperature 190°F Insert the coin(s) in the coin slot or card into the card (88°C) opening. Temperature 180°F Press START pad to start tumble dryer. (82°C) © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 114: Led Opl Control

    START ( ) pad must be pressed. When the cycle is complete, open door and remove laundry. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 115 18 hours or until the door is opened. S Models H Models Figure 48 U Models Y Models Figure 49 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 116: Unilinc Control

    After an hour the machine enters delayed tumble and will tumble for two minutes every hour for up to 18 hours or until the door is opened. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 117: Dx4 Coin Control

    Press and release one of the cycle buttons to select a cycle Button min. and start the tumble dryer. Refer to Table 32 . To use a custom cycle, refer to the Programming Manual. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 118: Diagnostic Microprocessor Control

    • Thermistor controlled temperature (66ºC) • Safety tumble cycle • Buzzer for end of cycle, audible alarm • Reversing/Nonreversing selection • Five user programmable programs © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 119 Time, Cooling Time, and Temperature. Then use the Up/ the sensor is bad. Down arrows to adjust the times and temperature. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 120: Dmp Opl Models

    11 COOLING LED. Illuminated when in the cooling cycle, or when the display is currently showing the time for the cooling cycle. 12 TEMPERATURE LED. Illuminated when the display is showing the temperature setting. Figure 54 Description of the OPL Control Panel © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 121 Coin, then DIP switch #7 in the ON position enables the display of the coin count. DIP switch #7 in the OFF Empty: Preset at the factory; always ON. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 122: Dmp Coin

    - START button to start or resume a cycle. The START button is used to step to the next parameter. After the last parameter, “End” will be flashing. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 123: Ignition Control Operation And Troubleshooting For Models Starting 3/11/13

    “PAy”. 1 Flash At Power Up 2 Flashes Flame Without Call For Heat 3 Flashes Ignition Lockout 4 Flashes (70458701 only) Manual Reset Error © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 124: Internal Control Failure

    Flame okay during TFI, no flame sense after TFI 1. Check electrode position and cleanliness. 2. Check high voltage wire. 3. Poor ground at burner. 4. Poor flame, check flame current. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 125: Proper Electrode Location

    19.8VAC. The control begins the ignition sequence after prepurge by powering the ignitor and opening the gas valve. The ignitor will © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 126: Ignition Control Operation For Ce Models Through 3/10/13

    TH and GND on the control. The Unexpected Presence of Flame test is performed when no flame is expected. Failure of this test results in the ignition © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 127: Diagnostic Led (Dgn Led)/Error Codes

    Gas Valve Not Connected 3 Red Flashes Ignition/Flame Sense Failure 4 Red Flashes Reset Switch is Shorted Slow Red and Low Voltage Green Flashes Detection © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 128: Adjustments

    To adjust the air shutter, loosen air inlet shutter adjusting Air Shutter Adjusting Screw screw. Open or close air shutter as necessary to obtain proper flame intensity. Figure 58 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 129: Airflow Switch

    If the actuating bracket does not operate the switch at the appropriate door closure, bend the actuating switch arm in or out to achieve proper actuation. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 130 Adjustments TMB997N Door Strike Screw Acorn Nut Figure 60 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 131: Maintenance

    Thermistor Cabinet Thermostat Guard Figure 62 T30, T45 Series Monthly Remove lint and debris from inside exhaust duct to maintain proper airflow and avoid overheating. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 132: Quarterly

    If the system test does not perform as indicated: Figure 63 Discontinue use of the tumble dryer. To perform the fire suppression system maintenance test: © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7...
  • Page 133 10. Lock the fire suppression system control box. 11. If the separate alarm option is being used, reconnect the auxiliary alarm output. 12. Start the tumble dryer to dry the test load. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 134: Before You Call For Service

    Tumble dryer is in Cool Down Mode. • • Lint screen clogged. Clean lint screen. • • Exhaust duct to outside is blocked. Clean out. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 135: Part No. 70458301Enr7 © Copyright, Alliance Laundry Systems Llc - Do Not Copy Or Transmit

    Turn off gas supply external to machine. Turn off manual gas shut-off valve on machine. Turn off steam supply external to machine. Remove all electric, gas and steam connections. © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 136: Disposal Of Unit

    Figure 65 © Part No. 70458301ENR7 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...