Baxi Combi 130 HE Installation & Servicing Instructions Manual page 20

Gas fired wall mounted condensing combination boiler
Table of Contents

Advertisement

Lower Door
Panel
Fig. 16
Fig. 17
20
Outer Case
Fixing Screw
Service Guidance Note
Label on inside of panel
8.0 Installation
8.3
Preparing The Boiler
1. Remove the outer carton.
2. Remove the lower door panel (Fig. 16).
3. Remove the outer case fixing screws (Fig. 16).
Slide the outercase upwards to disengage the
hooks on the backplate and remove (Fig. 17).
NOTE: Service Guidance Note Label is fitted
to the inside of the outercase (Fig. 17).
4. Remove the sealing plugs from the copper
bends.
5. Stand the boiler on its base by using the rear
lower edge as a pivot.
NOTE: A small amount of water may drain from
the boiler in the upright position.
Baxi declare that no substances harmful to
health are contained in the appliance or
used during construction of the appliance.