Baxi Combi 133 HE Plus Operating Instructions Manual

Baxi Combi 133 HE Plus Operating Instructions Manual

Gas fired wall mounted condensing combination boiler

Advertisement

User's Operating Instructions &
Important Warranty Information
Baxi Combi 133 HE Plus
Baxi Combi 100 HE Plus
Baxi Combi 80 HE Plus
Gas Fired Wall Mounted Condensing
Combination Boiler
Please keep these instructions in a safe place.
If you move house, please hand them over
to the next occupier.
© Baxi Heating UK Limited 2005

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Combi 133 HE Plus and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Baxi Combi 133 HE Plus

  • Page 1 User’s Operating Instructions & Important Warranty Information Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.
  • Page 2: Table Of Contents

    Warranty & Service Baxi is one of the leading manufacturers of domestic © Baxi Heating UK Limited 2005 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any heating products in the UK.
  • Page 3: Quick Reference Guide

    If the Red Flame Failure Light ( ) is ON or flashing, press the Reset button until the red light High goes OFF. If this occurs frequently a fault is indicated, Reset you should contact your installer. High © Baxi Heating UK Limited 2005...
  • Page 4: Troubleshooting

    Press the Reset Button Light ON until the red light goes off. Light FLASHING Light FLASHING High If the light Boiler indicators does not go Reset Button showing low Reset out or keeps pressure coming on High © Baxi Heating UK Limited 2005...
  • Page 5 Heating ON (see any instructions supplied with timer) If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible © Baxi Heating UK Limited 2005...
  • Page 6: Repressurising

    8. Disconnect the hose from the taps (a small amount of water may be present) and remove it. Keep the hose in a safe place for future use. Taps Copper Pipe Hose Fig. 3 Typical Filling Loop Wing Nut © Baxi Heating UK Limited 2005...
  • Page 7: Clearances

    11. It is important that the condensate drain system is not blocked, modified or damaged in any way as this would affect the operation of your boiler. Your installer should have insulated any exposed pipework. 320mm In Operation Fig. 5 © Baxi Heating UK Limited 2005...
  • Page 8: Care Of The Boiler

    3. The boiler incorporates an integral pump protection feature which continually monitors the time since the pump last operated. To prevent seizure, the pump will operate for approximately 1 minute if it has not run in the last 24 hours. © Baxi Heating UK Limited 2005...
  • Page 9: Legislation

    Checklist will be required in the event of any warranty work. Keep the instructions in a safe place and ensure that the Service Interval Record at the back is completed at each service visit. © Baxi Heating UK Limited 2005...
  • Page 10: Emergency

    90° clockwise (Fig. 7). 4. Call your Installer or Service Engineer as soon as possible. Gas Cock Heating Flow Fig. 7 Mains Water and Return Inlet © Baxi Heating UK Limited 2005...
  • Page 11 Notes © Baxi Heating UK Limited 2005...
  • Page 12: Warranty & Service

    12 Months Free Warranty - register today To receive your 12 months free warranty please complete the form supplied with the boiler or simply call heateam, the service division of Baxi Heating UK Limited on 08706 000 653. Our promise to you...

Table of Contents