Desiccant air dryer: Inspect for moisture in the air system by opening
reservoirs, draincocks or valves and checking for presence of water. The
presence of small amounts of water due to condensation is normal and is
not an indication that the dryer is not functioning properly.
Replace or rebuild the desiccant cartridge when you determine that the
desiccant is contaminated and does not have adequate water absorption
capacity. The desiccant change interval may vary. A general
recommendation is to replace the desiccant every 12 months (yearly). If
experience has shown that extended or shortened life has resulted for a
particular installation, then the yearly interval can be increased or
decreased accordingly.
system. Contact an authorized dealer if you are unsure of the air
reservoir locations or the draining procedure.
WARNING: Failure to drain air brake reservoirs can result in a
reduction or loss of braking ability due to fluid accumulation in
the reservoir and/or possible freeze-up during cold weather.
Hydraulic Brakes
Establish a regular schedule for periodic cleaning, lubrication and
adjustment inspection based on vehicle use. Exact maintenance intervals
are difficult to predetermine due to vehicle applications and operating
conditions. If you are uncertain of the proper schedule for your vehicle,
contact an authorized dealer.
Regular inspections should include:
• Checking the brake lining (every service interval). Establish
inspection intervals that provide for lining replacement before damage
to the disc occurs. Excessive lining wear may expose the backing
plate to the disc causing scoring of the disc faces. A qualified
technician should perform this inspection and keep to instructions
2015 F-650/750 (f67)
Owners Guide gf (ownloose), 1st Printing, December 2013
Canadian_French (fr_can)
Maintenance
Draining the air brake reservoir:
Completely drain all the air brake
reservoirs daily by opening the
draincock at the ends of the tanks.
(Where accessible. Pull-chains are
used when the drains are undercab
or otherwise inaccessible.) Close the
draincock after draining. Manually
drain any air tanks equipped with
automatic moisture ejector valves,
as required, to maintain a dry air
I n f o r ma t i o n P r o v i d e d b y :