Top Burner Valve Replacement; Pressure Regulator Removal; Convection Fan Removal; Oven Burner Removal - Viking VGR30 Service Manual

Free standing gas range
Table of Contents

Advertisement

VALVE REPLACEMENT
1.
Remove the control panel. (See control panel
removal.)
2.
Remove the lower valve blot and gasket.
3.
Lift the valve from the manifold.
NOTE: CHECK ALL CONNECTIONS FOR LEAKS
USING A SOAP SOLUTION AFTER INSTALLING
THE REPLACEMENT VALVE.

PRESSURE REGULATOR REMOVAL

1.
Shut off power to the oven.
2.
Shut off gas supply to the oven.
3.
Remove the left side grates, burner bowls and grate
supports.
4.
Disconnect the gas supply to the oven.
5.
Remove the regulator with a pipe wench turning
counter clock wise. (Secure the manifold with
another wrench before turning.)
NOTE: CHECK ALL CONNECTIONS FOR LEAKS
USING A SOAP SOLUTION AFTER INSTALL
REPLACEMENT REGULATOR. USE SEALANT
ON ALL PIPE JOINTS.
RESTIVE TO L.P. GAS. DO NOT USE THREAD
TAPE.

CONVECTION FAN REMOVAL

1.
Shut off power to the unit.
2.
Remove the control panel. (See control panel
removal.)
3.
Disconnect the wiring from the fan switch.
4.
Push the fan switch out of the control panel.
TOP BURNER VALVES
SEALANT MUST BE

OVEN BURNER REMOVAL

1.
Shut off power to the oven.
2.
Remove the oven door. (See oven door removal.)
3.
Remove the lower access panel below the oven
door by removing two (2) mounting screws on
either side under the oven door hinges.
4.
Disconnect the ignitors.
5.
Remove two (2) screws securing the oven burner.
6.
Remove the oven burner pulling forward until the
burner is free. (Be sure to align rear tab of the
burner with the mounting bracket in the oven when
replacing the burner.