Honeywell LYNX Touch User Manual page 64

Hide thumbs Also See for LYNX Touch:
Table of Contents

Advertisement

SYSTEM FUNCTIONS
Testing the System (to be conducted weekly)
❁ ✹
FAULT ZONES. Open each protected door and window in turn and listen for three beeps
from the control, followed by the zone's Voice Descriptor, if it is programmed. Identification
of each faulted protection point should appear on the display. The display will clear when the
door or window is closed.
Walk in front of any interior motion detectors (if used) and listen for three beeps and/or voice
descriptors, if programmed. The identification of the detector should appear on the display
when it is activated, and its voice descriptor will be announced (if programmed). The display
will clear when no motion is detected. Note that if wireless motion detectors are used, in
order to conserve battery life, there is a 3-minute delay between activations.
To test all smoke detectors, follow the manufacturer's instructions. The identification of each
detector should appear on the display when each is activated.
If a problem is experienced with any protection point (no confirming sounds, no display),
notify your service company.
When all protection points have been checked and are intact (closed), there should be no zone
identification numbers displayed on the touchscreen.
Exiting Test Mode
When testing is completed, exit the Walk Test or Dialer Test mode by entering an Off
sequence.
If the Walk Test mode is inadvertently left active, it automatically turns off after 4 hours. The Dialer
Test mode will remain active until exited via an Off sequence.
LYNX Touch SIA Exit/Entry Delay Times
The LYNX Touch SIA will send an event code to the Central Station after entering and after
exiting from Test mode.
✺ ✽
4. Select the
Walk Test
If Walk Test is selected proceed to Step 5. If
Dialer Test is selected proceed to Step 6
5.
Walk Test
status bar. Fault each zone as described
below.
6. If the dialer test is unsuccessful the system
will display a Reporter Failure message.
Contact your security service provider.
– 64 –
or
Dialer Test
is displayed on the system
icon.

Advertisement

Table of Contents
loading

Table of Contents