9.2.3 OP parameter
OP parameter is used to invert the polarity of the outputs.
⇒ 0 – normal
⇒ 1 – inverted
9.2.4 Table of parameters
Name
OS1
OD1
OD3
OD4
OP1
Example:
♦ Direct programming on the SIM card
Name
OS1
OD1
OP1
♦ Remote programming by SMS
;OS1=14;OD1=1;OP1=1;
9.3 DIRECT ACCESS BY ENTERING PIN ACCESS CODES
VIA ILLUMINATED KEYPAD
The user may control the predefined output by entering the PIN access codes. PIN
access code from 1 to 50 (PIN1 to PIN50) will activate the Output.
9.3.1 PIN1 to PIN50
PINx parameters are the PIN access codes for controlling the output.
Mode of operation for output 1
Input 1 direct link to outputs
GSM network problem direct link to outputs
NAC direct link to outputs
Invert control for output 1

Table 5: Output management parameters

ICE-LOCK PROGRAMMING TABLE
SIM CARD PHONE BOOK
Number
14
Mono-stable pulse mode (14s pulse)
1
Input 1 activates output 1
1
Output 1 inverted

Table 6: Output management parameters example