Figure 2: Input Connection Diagram; Table 1: In, Id And Dd Parameters; Table 2: In, Id, Dd Parameters Example - Transmitter Solutions ICE-LOCK Installation Manual

Gsm code lock access control unit
Table of Contents

Advertisement

ICE-­‐LOCK  
9.1.1.2
ID parameters
ID parameter determines time period of the pulse length to trigger the alarm. The
pulse time can be from 0,5 seconds to 9999 seconds. The default time is 0,5
seconds when the parameter value is 0.
Parameter is in seconds.
9.1.1.3
DD parameters
This parameter is used to define the delay between the time that alarm input is
trigged and the time that alarm is reported.
Parameter is in seconds.
9.1.1.4
Table of parameters
Name
IN1
ID1
DD1
Example:
♦ Direct programming on the SIM card
Name
IN1
ID1
DD1
♦ Remote programming by SMS
;IN1=0;ID1=10;DD1=15;

Figure 2: Input Connection diagram

Mode of operation for input 1
Input time integration delay on input 1
Time delay for alarm reporting on input 1

Table 1: IN, ID and DD parameters

ICE-LOCK PROGRAMMING TABLE
SIM CARD PHONE BOOK
Number
0
Alarm activated by connecting to GND
Input 1 has to be valid for 10 second to trigger
10
the alarm
Reporting of the alarm on input 1 is delayed by
15
15s

Table 2: IN, ID, DD parameters example