E L A N H O M E S Y S T E M S
EXT IR Input
IR signals can be sent from a location that is not part of a zone to control system sources.
Connect IR and GND wires as shown. An external power supply must be used to power an
IR receiver or keypad assigned to this function.
ELAN
Multi-Room
Controller or
IR Distribution
Block
IR Receiver
Figure 4.25 - EXT IR Input Connections-No PSS1
Sense Inputs
Plug in ELANSENSE sensors to created automated events based on triggers.
SENSE INPUTS
1
2
3
4
5
6
SS1
Figure 4.26 - Sense Input Connections-No PSS1
© ELAN Home Systems 2007 • All rights reserved.
IRIC
3.5mm Mono
Interconnect
Cable
OR
IR=Tip
GND=Sleeve
+12VDC
+12
VDC
RCA
Patch
Cables
SS1 System Station
SS1
EXT IR INPUT
SS1
Mono 3.5mm
Connector
EXT IR INPUT
Audio Source
Line-Level
Outputs
To
System
Amplifier
INSTALLATION MANUAL