Natural Gas Conversion - Patio Glow 98300 Assembly Instructions Manual

Palm bay lp firepit
Hide thumbs Also See for 98300:
Table of Contents

Advertisement

NATURAL GAS CONVERSION

Natural gas conversion must be performed only by your natural gas provider or service
company.
1. Disconnect the regulator hose from the gas valve. See Figure 14.
2. Disconnect the gas tube from the orifice elbow. Remove the two M4 nuts and remove
the orifice holder. Replace the propane orifice with the natural gas orifice from the kit
and reinstall the orifice holder. Apply a solution of soapy water to all connections to
check for leaks. If soap bubbles continue to form, the connection has a leak. If a leak
is found, close the main valve and tighten all connections. NEVER USE A FLAME
TO CHECK FOR LEAKS.
3. Stick the conversion label on the rating plate as shown in Figure 15.
Serial Number
CAUTION: The gas pressure regulator provided with this appliance must be used. This
regulator is set for an outlet pressure of 11 inches water column (2.7 kPa). The gas
supply must be turned off at the LP-gas supply cylinder when this appliance is not in
use.
This appliance has been converted to use Natural Gas.
Input 30,000 Btu/hr.
Max Gas Supply Pressure 7 inch water column(1.74 kPa) Min Gas Supply Pressure 5
inch water column (1.24 kPa)
FOR OUTDOOR USE ONLY. If stored indoors, detach and leave cylinder outdoors.
Figure 14
Metal Rating Plate
Model Number:
Figure 15
CONVERSION LABEL
12