Appendix 2: Friction Loss Tables - Franklin Electric Inline 400 Owner's Manual

Pressure boosting
Hide thumbs Also See for Inline 400:
Table of Contents

Advertisement

Available languages

Available languages

Appendix 2: Friction Loss Tables

¾" Pipe
Flow
Velocity
GPM
Ft / S
2
1.20
3
1.80
4
2 .41
5
3.01
6
3.61
7
4 .21
8
4 .81
9
5 .41
10
6.02
1" Pipe
Flow
Velocity
GPM
Ft / S
2
0.74
4
1 .48
6
2.23
8
2 .97
10
3.71
12
4 .45
14
5.20
16
5 .94
18
6 .68
1¼" Pipe
Flow
Velocity
GPM
Ft / S
4
0.86
6
1 .29
8
1 .72
10
2 .15
12
2 .57
14
3.00
16
3.43
18
3.86
20
4 .29
25
5.36
Note: Charts show friction loss per 100' of pipe. To convert to friction loss per foot, move decimal point two places to the left.
Inline Pressure Boosting System
Friction Loss
Ft Hd / 100'
Steel
PVC
(C = 100)
(C = 140)
1.93
1.03
4.09
2 .19
6 .96
3.73
10.53
5 .64
14 .75
7 .91
19.63
10.53
25.13
13.48
31.26
16 .76
38.00
20.38
Friction Loss
Ft Hd / 100'
Steel
PVC
(C = 100)
(C = 140)
0.60
0.32
2 .15
1 .15
4 .56
2 .44
7 .76
4 .16
11 .74
6 .29
16 .45
8 .82
21 .89
11 .74
28.03
15.03
34.86
18.70
Friction Loss
Ft Hd / 100'
Steel
PVC
(C = 100)
(C = 140)
0.57
0.30
1.20
0.64
2.04
1.10
3.09
1 .66
4.33
2.32
5 .76
3.09
7.38
3.96
9 .18
4 .92
11 .16
5 .98
16 .87
9.05
Fric Loss
Ft Hd / 100'
Velocity
Ft / S
Copper
(C = 130)
1.33
1.50
1 .99
3.18
2 .65
5 .42
3.31
8.20
3.98
11 .49
4 .64
15 .29
5.30
19 .57
5 .97
24.35
6.63
29 .59
Fric Loss
Ft Hd / 100'
Velocity
Ft / S
Copper
(C = 130)
0.78
0.41
1 .56
1 .48
2.33
3.14
3.11
5.35
3.89
8.08
4 .67
11.33
5 .44
15.07
6 .22
19.30
7.00
24.00
Fric Loss
Ft Hd / 100'
Velocity
Ft / S
Copper
(C = 130)
1.02
0.53
1.53
1.13
2.04
1 .92
2 .55
2.90
3.06
4.07
3.57
5 .41
4.08
6.93
4 .59
8 .62
5 .11
10.48
6.38
15 .85
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents