Grounding and Electric Requirements
D Ground solvent pails used when flushing. Follow local code. Use
only conductive, metal pails, placed on a grounded surface such as
concrete. Do not place the pail on a non–conductive surface such
as paper or cardboard, which interrupts the grounding continuity.
D Ground the metal pail by connecting a ground wire to the
pail by clamping one end to pail and the other end to
ground such as as water pipe.
D Maintain grounding continuity when flushing or
relieving pressure by holding metal part of spray gun
firmly to side of a grounded metal pail, then trigger gun.
To reduce risk of injury from motor staring
unexpectedly when it cools, always turn power
switch OFF if motor shuts down.

Thermal Overload

D Motor has a thermal overload switch
to shut itself down if overheated.