Troubleshooting Procedures

!
Directions for System Diagnosis Flow Chart
A test set-up is described at the beginning of each test sequence. Directly below the test set-up is a description of
the normal oven operation(s) (identified by a question mark).
If oven operation is normal, follow the YES sequence down the left side of the page.
If oven operation is abnormal, follow the NO sequence to the right side of the page.
To effectively use this flow chart, the directions below must be followed:
• Always start at test sequence 1, perform each test set-up, do not skip test sequences.
• Verify normal operation(s) following each test set-up before going on to the next test sequence or set-up.
• When abnormal operation is identified, disconnect power to the oven, DISCHARGE CAPACITOR(S), determine
cause starting with the first possible cause, correct the failure, then start over at test sequence one to verify
normal operation.
NOTE: Always check for failed or improper wiring before servicing.
Diagnosis for VEND-10.000, .A, .B, .C, FS-10EVP, FS-14, FSP-10
Test Sequence 1: Idle Condition
Open oven door and connect power cord.
Colon appears in the display?
Yes
Close oven door
Cavity light is on?
Yes
Does the blower motor operates?
Yes
Stirrer motor operates?
Yes
"Idle" operation normal.
Proceed to "Cook" condition
(Test Sequence 2).
RE220002 Rev. 6`
WARNING
To avoid risk of electrical shock, personal injury, or death,
disconnect power to unit and discharge the capacitor
before following any disassembly procedures.
1. No power applied to the oven power cord.
2. Blown fuse (Note: Check interlock switch
module operation, monitor test).
No
3. Inoperative cavity thermal protector.
4.
Inoperative low voltage transformer.
5.
Inoperative controller.
6.
Broken or improper wire connection.
1.
Inoperative holding relay.
2.
Inoperative controller.
3. Inoperative low voltage transformer.
No
4.
Inoperative cavity light or socket.
5.
Broken or improper wire connection.
No
1. Blower motor inoperative or binding.
2. Broken or improper wire connection.
No
1. Inoperative or binding stirrer motor.
2. Broken or improper wire connection.