Inspection and maintenance work – Overview
F
The table below lists the manufacturer requirements with respect to minimum inspection and maintenance intervals. If na-
tional regulations and directives require shorter inspection and maintenance intervals, you should observe these instead of
the intervals listed in the table.
No.
Work
Check the air/flue pipe for leak-tightness and to ensure that it is fastened correctly. Make sure
1
that it is not blocked or damaged and has been installed in accordance with the relevant Installa-
tion Manual.
Check the general condition of the product. Remove dirt from the product and from the vacuum
2
chamber.
Visually inspect the general condition of the Thermoblock. In doing so, pay particular attention
3
to signs of corrosion, rust and other defects. If you notice any damage, carry out maintenance
work.
Check the gas flow pressure at maximum heat input. If the gas flow pressure is not within the
4
correct range, carry out maintenance work.
Check the CO₂ content (the air ratio) of the product and, if necessary, adjust it. Keep a record of
5
this.
Disconnect the product from the power mains. Check that the electrical plug connections and
6
other connections are seated correctly and correct these if necessary.
Close the gas isolator cock and the service valves.
7
Drain the product on the water side (observe the pressure gauge). Check the pre-charge pres-
8
sure of the expansion vessel, and top up the vessel if necessary (approx. 0.03 MPa/0.3 bar un-
der the system filling pressure).
Check the pre-charge pressure in the shift-load cylinder expansion vessel. Correct the pressure,
9
if necessary.
Remove the compact thermal module.
10
Check the insulating mats in the combustion area. If you notice any damage, replace the insu-
11
lating mats. Replace the burner flange seal each time it is opened and accordingly each time
maintenance work is carried out.
Clean the heat exchanger.
12
Check the burner for damage and replace it if necessary.
13
Check the condensate trap in the product, clean and fill this, if required.
14
15
Install the compact thermal module. Caution: Replace the seals.
If the volume of water is insufficient or the outlet temperature is not reached, replace the second-
16
ary heat exchanger if necessary.
Clean the filter in the cold water inlet. Replace the filter if impurities can no longer be removed
17
or if the filter is damaged. In this case, also check the impeller sensor for dirt and damage, clean
the sensor (do not use compressed air for this) and replace the sensor if it is damaged.
Open the gas isolator cock, reconnect the product to the power mains and switch the product on.
18
0020209593_01 ecoTEC plus Installation and maintenance instructions
13
Bus connection (digital room thermostat/controller)
14
Diverter valve
15
Water pressure sensor
16
Impeller sensor
17
Warm start sensor
18
Hot water sensor
19
Gas group coding resistor
20
Auxiliary relay (select via D.026)
21
Internal pump
22
Ignition electrode
*
Depending on product type
Appendix
Mainten-
ance
(must be
Inspection
(annual)
carried out
at regular
intervals)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents