Appendix
Code Parameter
D.064 Average ignition time
D.065 Maximum ignition time
D.067 Remaining burner anti-cycling time
D.068 Unsuccessful ignitions at 1st attempt
D.069 Unsuccessful ignitions at 2nd at-
tempt
D.070 Set diverter valve position
D.071 Target value maximum heating flow
temperature
D.072 Internal pump overrun after cylinder
charging
D.073 Warm start target offset
D.074 actoSTOR anti-legionella function
D.075 Max. charging time for domestic hot
water cylinder without independent
control system
D.076 Device Specific Number Device
specific number = DSN)
D.077 Limit on cylinder charging output in
kW
D.078 Limit on cylinder charging temperat-
ure in °C
D.080 Operating hours, heating
D.081 Operating hours, hot water genera-
tion
D.082 Number of burner start-ups in heat-
ing mode
D.083 Number of burner start-ups in hot
water mode
D.084 Maintenance indicator: Number of
hours until the next maintenance
D.088 Start delay for hot water draw-off
detection via impeller (only products
with integrated hot water generation)
D.090 Status of digital controller
D.091 Status of DCF with external temper-
ature sensor connected
D.092 actoSTOR module recognition
D.093 Setting the Device Specific Number
(DSN)
46
Values or explanations
In seconds
In seconds
In minutes
Number of unsuccessful ignitions
Number of unsuccessful ignitions
0 = Normal operating mode
1 = Parallel operation (mid-position)
2 = Permanent heating mode position
40 ... 80 ℃
Adjustable from 0-10 minutes in increments of 1 minute
Adjustable from -15 K to 5 K
0 = Off
1 = On
20 - 90 min
17 = 938 (VUI GB 386/5-5 A)
Adjustable cylinder charging output in kW
50 °C - 80 °C
Note
The chosen value must be at least 15 K or 15 °C above
the set cylinder target value.
In hours (h)
In hours (h)
Number of burner start-ups
Number of burner start-ups
Adjustment range: 0 to 3000 hrs and "---" for deactivated
0 = 1.5 l/min and no delay,
1 = 3.7 l/min and 2 sec. delay
Recognised, not recognised
No reception
Reception
Synchronised
Valid
0 = Not connected
1 = Connection error: No communication via PeBus,
actoSTOR module detected previously
2 = Connection active
Setting range: 0 to 99
Installation and maintenance instructions ecoTEC plus 0020209593_01
Default
Own setting
setting
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
0 = Normal
operating
mode
75 ℃
2 mins
0
1 = On
45 mins
Not ad-
justable
75 °C
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
„---"
1.5 l/min and
no delay
Not ad-
justable
Not ad-
justable
Not ad-
justable

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents