Appendix; A Detecting And Eliminating Faults; Inspection And Maintenance Work - Overview - Vaillant uniSTOR HP VIH RW GB BES Series Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

Appendix

Appendix
A
Detecting and eliminating faults
Fault
Possible cause
No flow rate at the valve
1.
2.
3.
Low throughput and
1.
pressure at a valve
Water from the valve is
1.
cold
2.
3.
4.
5.
Domestic hot water
1.
temperature too high
2.
3.
4.
Irregular domestic hot
1.
water output at the valve
2.
Continuous water leak
1.
(dripping)
2.
Continuous water leak
1.
(flowing out quickly)
Continuous water leak
1.
(flowing out quickly with
hot water vapour)
Inspection and maintenance work – Overview
B
Work
1
Check the connections for tightness.
2
Check the temperature and pressure expansion relief valve.
3
Check the expansion relief valve.
4
Check the pressure in the expansion vessel.
5
Check the domestic hot water output at the valve (if required, clean the filters).
6
Check the target domestic hot water temperature.
7
Fill out the cylinder's benchmark checklist.
16
Water supply valve closed
Main filter blocked
Pressure reducer not installed correctly
Filter in cold water supply clogged
The cylinder was not set or is not operating.
The heat generator does not work.
The thermal cut-out was triggered.
Motorised valve does not work
The immersion heater does not work.
Use a thermometer to check the temperature; it
must be between 60 and 65 °C.
Check the cabling.
Thermostat set too high
Defective thermostat
Defective expansion vessel
Thermal control
Expansion relief valve fault
Temperature and pressure relief valve fault.
Malfunction in the pressure reducer.
Temperature and pressure relief valve opened
due to an excessively high temperature.
Remedy
1.
Check and open the valve.
2.
Close the water supply valve, clean the filter
and the water pressure reducer.
3.
Check whether the pressure reducer has been
installed correctly.
1.
Close the cold water supply, clean the filter for
the water pressure reducer.
1.
Check the thermostat or the room thermostat
and, if required, set this.
2.
Check the heat generator; a fault code is
present.
3.
Check and initialise the cylinder.
4.
Check the valve's connections.
5.
Set the thermostat or the room thermostat.
1.
Install a mixer tap.
2.
Repair the cable.
3.
Reduce the temperature of the thermostat to
55 °C.
4.
Replace the thermostat.
1.
Set the expansion vessel.
2.
Interrupt the power supply of the product and
heat generator, check the thermal cut-outs and
replace these if you find any defects.
1.
Determine the part that is causing the continu-
ous water leak.
2.
Replace the defective parts.
1.
Check the pressure at the pressure reducer
outlet.
2.
Replace the pressure reducer if the pressure is
above 3.5 bar.
1.
Switch off the power supply to the immersion
heater.
2.
If the immersion heater is not switched on,
switch off the power supply to the cylinder.
3.
Contact a competent person.
Installation and maintenance instructions uniSTOR HP 0020221303_02
Maintenance-re-
lated interval
Annually
Annually
Annually
Annually
Annually
Annually
Annually